FAA Advisory circularActive

AC 20-158B

The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment

20-158B Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.

Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3

Source page 49 · PDF page 49

05/20/24 AC 20-158B Appendix A

A.2.2.5 32 dB Attenuation.

This attenuation is appropriate when the level A display equipment and all associated wiring to and from equipment are located entirely within areas with very effective HIRF shielding to form an electromagnetic enclosure.

A.2.2.6 Generic Attenuation for Rotorcraft.

Display units installed in rotorcraft typically have minimal attenuation unless specific shielding is provided in the bulkhead, glare shield, panel, and doors.

A.2.3 Different attenuation values may be appropriate for different frequency ranges. For example, 0 dB attenuation may be used for the frequency range of 100 MHz to 400 MHz, 6 dB attenuation for the frequency range of 400 MHz to 1 GHz, and 12 dB attenuation for the frequency range of 1 GHz to 18 GHz. If you intend to use different attenuation values for various frequency ranges, then you should also provide the supporting rationale.

A.2.4 Consult the user’s guide for details on the use of generic attenuation.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-158A

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.