FAA Advisory circularActive

AC 20-158B

The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment

20-158B Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.

Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3

Source page 41 · PDF page 41

10.16.2 below. Level 4 airplanes certified under part 23 meet the requirements for HIRF as shown in paragraph 10.5 (Step 5 - Integrated System Test).

Note: The applicant may also use a means of compliance, which may include ASTM consensus standards, accepted by the Administrator under § 23.2010. (See paragraph 4.4).

10.16.1 For level 1 airplane HCL A systems, you may perform integrated system conducted and

radiated susceptibility tests using RTCA/DO-160E (refer to AC 21-16), section 20, category R.

10.16.2 For level 2 and 3 airplane HCL A systems, you may perform integrated system

conducted susceptibility tests per the Generic Conductive Curve — < 25 meters extrapolated to Environment I and using the applicable levels defined in RTCA/DO- 160G (refer to AC 21-16), section 20, category M.

Note: RTCA/DO-160E, section 20, category A is also acceptable.

10.16.3 For level 2 and 3 airplane HCL A systems, you may perform integrated system radiated

susceptibility tests per the Aircraft Generic Attenuation Curves applied to Environment I and using the applicable levels described below (RTCA/DO-160G, refer to AC 21-16).

• 0 dB: 100 MHz – 400 MHz (using RTCA/DO-160G, section 20, category G)

• -6 dB: 400 MHz – 1 GHz (using RTCA/DO-160G, section 20, category F)

• -12 dB: 1 GHz – 18 GHz (using RTCA/DO-160G, section 20, category D)

10.16.4 You may design and install the engine control systems using the guidance provided in

AC 33.28-3. You may develop and install appropriate electrical bonding features for the engine control systems using the guidance in AC 33.28-3.

10.16.5 Electrical bonding specifications and verifications should be developed and

implemented on the production drawings and instructions for continued airworthiness.

11 STEPS TO LEVEL B AND C SYSTEM HIRF COMPLIANCE

Steps 1 through 8 listed below for HCL B and C systems HIRF compliance may be used to show compliance with §§ 23.1308(b) and (c), 23.2520(b), 25.1317(b) and (c), 27.1317(b) and (c), or § 29.1317(b) and (c).

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-158A

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.