HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
10 STEPS TO LEVEL A SYSTEM HIRF COMPLIANCE
Steps 1 through 15 listed below for HCL A system HIRF compliance may be used to show compliance with §§ 25.1317(a), 27.1317(a), or § 29.1317(a). Airplanes certificated under part 23 may use steps 1 through 15 to show compliance with § 23.1308(a) or § 23.2520(a), but acceptable compliance for HCL A systems on level 1, 2, 3, and 4 airplanes certificated under part 23 may also be shown using the method in paragraph 10.16 below.
10.1 Step 1 — HIRF Safety Assessment.
10.1.1 Determine the system failure condition classification for the systems being certified on your aircraft, using a system safety assessment as discussed in paragraphs 7.2 and 7.3. For systems classified with catastrophic failure conditions (HCL A systems), follow compliance steps 2 through 15 listed below, as appropriate. Figures 1 and 2 of this AC also depict these compliance steps, which are not necessarily accomplished sequentially. Systems classified with hazardous or major failure conditions (HCL B and C systems) should follow the compliance steps outlined in paragraph 11.
10.1.2 When showing compliance with §§ 23.1308(a), 23.2520(a), 25.1317(a), 27.1317(a), or § 29.1317(a), the level A electrical and electronic system includes all electrical and electronic equipment, components, and electrical interconnections required to perform the function whose failure would prevent continued safe flight and landing. This electrical and electronic system must also recover normal operation of the level A functions in a timely manner to comply with §§ 23.1308(a)(2), 23.2520(a)(2), 25.1317(a)(2), 27.1317(a)(2), or § 29.1317(a)(2). The level A electrical and electronic system is not required to include:
• Equipment, components, and electrical interconnections required only for non-
normal situations; or
• Equipment, components, and electrical interconnections required only for dispatch
under a minimum equipment list.
10.1.3 Some systems include mechanical, hydraulic, and/or pneumatic channels as well as electrical and electronic elements or channels that perform functions whose failure would prevent continued safe flight and landing. The HIRF safety assessment for §§ 23.1308(a), 23.2520(a), 25.1317(a), 27.1317(a), or § 29.1317(a) only applies to functions performed by electrical and electronic systems. The HIRF safety assessment should consider electrical or electronic failures that would adversely affect the function of the mechanical, hydraulic, and/or pneumatic channels. If electrical or electronic equipment, components, and electrical interconnections are used to assist, augment, or monitor for control loop feedback, the mechanical, hydraulic, and/or pneumatic channels in performing functions with failures that would prevent continued safe flight and landing during normal operation, then the electrical and electronic channel(s) must comply with §§ 23.1308(a), 23.2520(a), 25.1317(a), 27.1317(a), or § 29.1317(a).
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source