AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
• Susceptibility Level. Level where the effects of interference from electromagnetic
energy become apparent.
• Timely Manner. The necessary period for a system to reconfigure safely after a
disruption.
Note: Timely recovery has been introduced to account for this period. The meaning of ‘in a timely manner’ depends on the function performed by the system being evaluated, the specific system design, the interactions between the system and the flightcrew, and the phase of flight. The definition of ‘in a timely manner’ should be determined for each system and for the specific functions performed by the system. The applicable definition may be included in the HIRF safety assessment.
• Transfer Function. Ratio of the electrical output of a system to the electrical input of
a system, expressed in the frequency domain. For HIRF, a typical transfer function is the ratio of the current on a wire bundle to the external HIRF field strength, as a function of frequency.
• Upset. Impairment of system operation, either permanent or momentary. For
example, a change of digital or analog state that may or may not require a manual reset.
6 BACKGROUND
Electrical and electronic systems installed in aircraft may exhibit performance degradation when exposed to a HIRF environment. These systems perform functions whose failure may prevent the continued safe flight and landing of the aircraft or cause an adverse operating condition.
6.1 HIRF Environment.
The electromagnetic HIRF environment is created because of the transmission of electromagnetic RF energy from radar, radio, television, and other ground-based, shipborne, or airborne RF transmitters. The user’s guide, SAE ARP5583A or EUROCAE ED-107A, provides a detailed description of the derivation of these HIRF environments.
6.2 Aircraft Protection.
Concerns over the need to protect aircraft electrical and electronic systems have increased substantially because of:
• Greater dependence on electrical and electronic systems performing functions
required for continued safe flight and landing of an aircraft;
• Reduced electromagnetic shielding afforded by some composite materials used in
aircraft designs;
• Increased susceptibility of electrical and electronic systems to HIRF because of
increased data bus and processor operating speeds, higher density integrated circuits, and greater sensitivities of electronic equipment;
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source