AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
• HIRF Vulnerability. Susceptibility characteristics of a system that cause it to suffer
adverse effects when performing its intended function because of having been subjected to a HIRF environment.
• Immunity. Capacity of a system or piece of equipment to continue to perform its
intended function, in an acceptable manner, in the presence of RF fields.
• Interface Circuit. Electrical or electronic device connecting the electrical inputs and
outputs of equipment to other equipment or devices in an aircraft.
• Internal HIRF Environment. The RF environment inside an airframe, equipment
bay, or cavity. The internal RF environment is described in terms of the internal RF field strength or wire bundle current.
• Margin. Difference between equipment susceptibility or qualification levels and the
aircraft internal HIRF environment. Margin requirements may be specified to account for uncertainties in design, analysis, or test.
• Modulation. Process whereby certain characteristics of a wave, often called the
carrier wave, are varied in accordance with an applied function.
• Normal Operation. The status where the system is performing its intended function.
When addressing compliance with §§ 23.1308(a)(2), 23.2520(a)(2), 25.1317(a)(2), 27.1317(a)(2), and 29.1317(a)(2), the function whose failure may prevent the continued safe flight and landing should be in the same undisturbed state as before exposure to the HIRF environment.
• Non-Normal Situation. An event, condition, or situation that requires non-normal,
abnormal, emergency, or unusual procedures or configurations for operating the aircraft.
• Pulse Modulation. RF signal in the form of pulses with varied amplitudes and
widths (narrowband or broadband).
• Radio Frequency. Frequency within the range used for radio transmission. The
present practical range of RF transmissions are roughly 10 kilohertz (kHz) to 100 gigahertz (GHz). Within this frequency range, electromagnetic energy may be detected and amplified as an electric current at the wave frequency.
• Reflection Plane. Conducting plate that reflects RF signals.
• Similarity. Process of using existing HIRF compliance documentation and data from
a system or aircraft to demonstrate HIRF compliance for a nearly identical system or aircraft of equivalent design, construction, and installation having equivalent internal and external environmental conditions.
• Square Wave. RF signal that alternates amplitude, with the same duration, between
fixed minimum and maximum values.
• Susceptibility. Aspect of a piece of equipment that describes its inability to function
acceptably when subjected to unwanted electromagnetic energy.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source