AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
11.1 Step 1 — System Safety Assessment.
Determine the system failure condition classification for the systems being certified on your aircraft, using a system safety assessment as discussed in paragraph 7.3. For systems classified with hazardous or major failure conditions (level B and C systems), follow compliance steps 2 through 8 listed below, as appropriate. These compliance steps are also depicted in figure 3 of this AC and are not necessarily accomplished sequentially. Systems classified with catastrophic failure conditions (level A systems) should follow the compliance steps outlined in paragraph 10.
11.2 Step 2 — Define Aircraft and System HIRF Protection.
Define the HIRF protection features incorporated into the aircraft and system designs, based on the HIRF test levels applicable to your aircraft and its level B and C systems. Equipment, system, and aircraft HIRF protection design may occur before you perform aircraft-level tests, and before you determine the actual internal HIRF environment. Therefore, you should base the equipment, system, and aircraft HIRF protection design on an estimate of the expected internal HIRF environment.
11.3 Step 3 — Select Compliance Method.
Determine if you will perform equipment HIRF tests on the level B and C systems, or if you will base the compliance on previous equipment tests performed for a similar system.
11.4 Step 4 — Equipment Test.
Level B and C systems do not require the same degree of HIRF compliance testing as level A systems, and therefore do not require aircraft-level testing. You should follow RTCA/DO-160E, section 20 (as specified in AC 21-16) laboratory test procedures, using the equipment test levels defined in the regulations. The test levels used depend on whether the system is categorized as level B or C. Equipment HIRF test level 1 or 2, as applicable, should be used for level B systems. RTCA/DO-160E, section 20, Category RR, satisfies the requirements of equipment HIRF test level 1. For equipment HIRF test level 2, you may use the approach in paragraph 10.11 of this AC to determine acceptable aircraft transfer function and attenuation curves for your level B system. Equipment HIRF test level 3 should only be used for level C systems. RTCA/DO-160E, section 20, category TT, satisfies the requirements of equipment HIRF test level 3. When applying modulated signals, the test levels are given in terms of the peak of the test signal as measured by a root-mean-square (rms) indicating spectrum analyzer's peak detector. See the user’s guide for more details on modulation.
11.4.1 Define appropriate pass/fail criteria for the system, based on the system safety assessment and the appropriate HIRF regulation (see paragraph 7.3). Any susceptibility noted during the equipment tests, including equipment malfunctions, upset, or damage, should be recorded and evaluated based on the defined pass/fail criteria.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source