AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
05/20/24 AC 20-158B Appendix A
A.2 GENERIC ATTENUATION.
A.2.1 Figure A-6 shows the generic attenuation for frequencies from 100 MHz to 18 GHz that can be used for determining the internal HIRF environment where equipment and associated wiring for level A display systems (see paragraph 10.11) are installed. This internal HIRF environment provides the radiated susceptibility test level for the laboratory integrated system test. The external HIRF environment should be divided by the appropriate attenuation, in linear units, to determine the internal HIRF environment. For example, 12 dB or a 4:1 attenuation means the test level is the applicable external HIRF environment electric field strength reduced by a factor of 4.
A.2.2 Guidance on the use of the generic attenuation is given below:
A.2.2.1 No Attenuation.
No attenuation credit can be used when the level A display equipment and associated wiring are located in aircraft areas with no HIRF shielding, such as areas with unprotected nonconductive composite structures, areas where there is no guarantee of structural bonding, or other open areas where no shielding is provided. You may choose to use no attenuation for equipment that may be installed in a broad range of aircraft areas.
A.2.2.2 6 dB Attenuation.
This attenuation is appropriate when the level A display equipment and associated wiring are located in aircraft areas with minimal HIRF shielding, such as a cockpit in a nonconductive composite fuselage with minimal additional shielding, or areas on the wing leading or trailing edges, or in wheel wells.
A.2.2.3 12 dB Attenuation.
This attenuation is appropriate when the level A display equipment and associated wiring are located entirely within aircraft areas with some HIRF shielding, in aircraft with a metal fuselage or a composite fuselage with shielding effectiveness equivalent to metal. Examples of such areas are avionics bays not enclosed by bulkheads, cockpits, and areas near windows, access panels, and doors without EMI gaskets. Current- carrying conductors in this area, such as hydraulic tubing, control cables, wire bundles, and metal wire trays, are not all electrically bonded to bulkheads they pass through.
A.2.2.4 20 dB Attenuation.
This attenuation is appropriate when the level A display equipment and associated wiring are located entirely within aircraft areas with moderate HIRF shielding, in aircraft with a metal fuselage or a composite fuselage with shielding effectiveness equivalent to metal. In addition, wire bundles passing through bulkheads in these areas have shields electrically bonded to the bulkheads. Wire bundles are installed close to metal structure and take advantage of other inherent shielding characteristics provided by metal structure. Current-carrying conductors, such as hydraulic tubing, cables, and metal wire trays are electrically bonded to all bulkheads they pass through.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source