EASA Means of ComplianceFinal — current published edition checked

MOC-3 SC-VTOL

Means of Compliance with SC-VTOL — Batch 3

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 3 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Third final batch, addressing propulsion battery thermal runaway and related safety considerations.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 8e7b1d83ad81cb96d502ea069c20636566899a735e683c7e0a4576aa98a4f0e6

Source page 11 · PDF page 11

Third Publication of Means of Compliance with the Special

Doc. No: MOC-3 SC-VTOL Issue: 2 Date: 21 June 2023

Condition VTOL

(D) No escape of flames or emissions outside of the battery system and/or Explosive Fire

Zone, except through the designed venting provisions. (E) No compromise of warning signals and safety functions (e.g., battery automatic

disconnect function).

(b) Thermal Runaway Containment for CSFL time Tests

Experience has demonstrated that, although very unlikely, more than a cell could go into thermal runaway due to an unforeseen failure mode. Therefore, the applicant should define in coordination with EASA, a set of tests to demonstrate that realistic worst-cases of thermal runaway in more than a cell can be managed at propulsion battery system level and installation level (Battery Explosive Fire Zone) ensuring continued safe flight and landing in accordance with EASA MOC VTOL.2330 “Fire Protection in designated fire zones”.

The following guidelines should be considered for the development of Thermal Runaway Containment for CSFL time Tests:

(i) Aging and environmental conditions during operation may result in degradation of the

electrochemical properties and protection layers for each battery. Therefore, to test the worst-cases conditions during the life of the propulsion battery system, these tests should also be performed with battery systems that have experienced loading that could lead to such degradation, i.e., vibrations, thermal cycling and electrical cycling, either on separate test articles or sequentially on the same test articles. Battery systems used for RTCA DO-160/EUROCAE ED-14 environmental tests and aging cycle tests (iaw. EUROCAE ED-289) can be used as test samples when the applicant demonstrates a proper aging and degradation. Alternatively, battery systems that have gone through equivalent accelerated life tests can also be used.

(ii) All the parameters identified in Section 7.(a)(3)(ii) (Guidelines for development of

Thermal Runaway Non-Propagation Tests) for the full characterisation of thermal runaway behaviour at cell level should be also considered to determine the potential worst-cases for Thermal Runaway Containment tests.

(iii) A thermal runaway in at least 20% of the cells in the propulsion battery system should

be caused by the worst-cases of combinations of test conditions as determined in the previous point 7.(b)(2)(ii).

(iv) Triggered cells should be selected as follows:

(A) To maximize the potential for propagation to other cells, the spacing and heat

transfer characteristics between cells should be assessed. (B) The battery system configuration, the location of the cells within the battery system,

and point 7.(b)(2)(ii) should be assessed to justify the selection of cells that have potential to be worst cases to be tested (e.g. centre, wide face, narrow face, corner, edge, subgroup of triggered cells in different sides, …)

(v) The tested battery system should be representative of the type design configuration,

and should include the installation into the aircraft, designated venting provision,

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC-3 SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.