EASA Means of ComplianceFinal — current published edition checked

MOC-3 SC-VTOL

Means of Compliance with SC-VTOL — Batch 3

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 3 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Third final batch, addressing propulsion battery thermal runaway and related safety considerations.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 8e7b1d83ad81cb96d502ea069c20636566899a735e683c7e0a4576aa98a4f0e6

Source page 5 · PDF page 5

Third Publication of Means of Compliance with the Special

Doc. No: MOC-3 SC-VTOL Issue: 2 Date: 21 June 2023

Condition VTOL

Only one test article is tested. There is no characterisation of thermal runaway behaviour at cell level for different parameters. The variability in the characteristics of the cells, or the possibility of having defective cells within the battery system, may lead to trigger very few cells at temperatures lower than the thermal runaway initiation temperature of most of the cells. As the power to the heating device may be removed once a thermal runaway has initiated, it could lead to have only those very few cells into thermal runaway. If a thermal runaway occurs in at least two cells, the objective of the test is already met. Degradation of the propulsion battery containment due to aging and environmental conditions during operation is not considered.

(d) The design of electronics for critical aviation applications has been practiced for decades in the industry

and demonstrated as highly effective for the safe operation of aircraft when consistent with appropriate industry practices. Therefore, as for any other system in the aircraft, if designed protections are shown to be reliable, the overall risk testing should consider these protections and their reliability.

Considering this, two acceptable approaches are proposed in this Means of Compliance to address the demonstration of an adequate mitigation of battery system thermal runaway conditions for VTOL aircraft in the category enhanced.

This Means of Compliance is neither addressing nor superseding other tests and considerations needed for the certification of propulsion battery systems (i.e., external short circuit, available system capacity and energy, protections testing, battery system crashworthiness tests, HV signage…).

This Means of Compliance is predicated on battery technologies and chemistries that are currently known and ready for use. Future technologies and chemistries might require additional or alternative considerations that should be first established at project level.

Reference Documents

The following references have been used as a source of information or to provide accepted methods and practices:

(a) RTCA DO-311A “Minimum Operational Performance Standards for Rechargeable Lithium Batteries and

Battery Systems”, December 19, 2017. (b) RTCA DO-160G/EUROCAE ED-14G “Environmental Conditions in Airborne Systems and Equipment”. (c) ED-289 “Guidance on Determination of Accessible Energy in Battery Systems for EVTOL Applications”. (d) ED-312 “Guidance on Determining Failure Modes in Lithium-Ion Cells for eVTOL Applications”. (e) RTCA DO-227A “Minimum Operational Performance Standards for Non-Rechargeable Lithium

Batteries”. (f) EASA AMC 20-115 “Airborne Software Development Assurance Using EUROCAE ED-12 and RTCA DO-

178”. (g) EASA AMC 20-152 “Development Assurance for Airborne Electronic Hardware (AEH)”. (h) SAE ARP 4761 “Guidelines and Methods for Conducting the Safety Assessment Process on Civil Airborne

Systems and Equipment”. (i) EASA MOC VTOL.2330 “Fire Protection in designated fire zones”.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC-3 SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.