EASA Means of ComplianceFinal — current published edition checked

MOC-3 SC-VTOL

Means of Compliance with SC-VTOL — Batch 3

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 3 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Third final batch, addressing propulsion battery thermal runaway and related safety considerations.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 8e7b1d83ad81cb96d502ea069c20636566899a735e683c7e0a4576aa98a4f0e6

Source page 4 · PDF page 4

Third Publication of Means of Compliance with the Special

Doc. No: MOC-3 SC-VTOL Issue: 2 Date: 21 June 2023

Condition VTOL

MOC – SUBPART E – LIFT/THRUST SYSTEM INSTALLATION

MOC VTOL.2440 Propulsion Batteries Thermal Runaway for VTOL category enhanced

Introduction

Compliance with VTOL.2440, but also with VTOL.2330, VTOL. 2400(d), VTOL.2425(a), VTOL.2430 (a)(1)(5), (b)(2), (c)(3), (d), VTOL.2510, and VTOL.2525 requires demonstrating that the hazards from a fire in the propulsion battery system will be appropriately prevented and mitigated.

The latest rechargeable lithium battery systems minimum operational performance standard RTCA DO-311A is a useful baseline for developing and testing propulsion battery systems. However, its “Thermal runaway containment test”, in section 2.4.5.5, was developed for lithium batteries that provide power to other aircraft systems or equipment. Therefore, the standard did not necessarily consider the particularities of battery systems intended to be used for electric and hybrid aircraft propulsion.

That containment test, when applied to propulsion battery systems, may lead to decrease their energy/weight ratio unduly and substantially, because of placing the focus on the containment of an unprecedented thermal runaway event instead of considering the implementation of different protection layers and the containment of a realistic worst-case thermal runaway event. While this test could be accepted as means of compliance, provided that other requisites are also met, it should not alleviate the implementation of appropriate protective layers/measures.

In this Means of Compliance, EASA proposes an alternative test method for propulsion lithium batteries, to promote best industry practices, robust designs, and protection layers strategies for the entire propulsion battery system. Moreover, this alternative intends to foster innovation and development of new solutions for these battery system protection layers, instead of relying only on containment mitigations.

The main reasons for this alternative method to RTCA DO-311A section 2.4.5.5. “Thermal Runaway Containment Test” are:

(a) The amount of additional external energy put into the battery system for this test is far in excess of

energies used in service, which are limited by fail-safe protection layers and proper design, manufacturing, installation, operation, and maintenance.

Depending upon the chemistry, rechargeable lithium batteries can accept overcharging levels that lead to double the normal energy before reaching a point of chemical and thermal instability. Heating the whole battery could compromise the validity of the test results due to mechanical and thermal effects created by pre-heating the whole battery structure, materials, and components to high temperatures.

(b) In some cases, overcharging (if feasible) or overheating the whole battery can drive a near-simultaneous

failure of all cells in the battery, which would not represent a realistic in-service field failure, but an extreme condition not encountered in service, even in batteries where reliable and tested protection layers were not implemented.

(c) However, in other cases, this test may lead to undertest the propulsion battery containment, since:

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC-3 SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference