MOC-3 SC-VTOL
Means of Compliance with SC-VTOL — Batch 3
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 3 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Third final batch, addressing propulsion battery thermal runaway and related safety considerations.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 8e7b1d83ad81cb96d502ea069c20636566899a735e683c7e0a4576aa98a4f0e6
Third Publication of Means of Compliance with the Special
Doc. No: MOC-3 SC-VTOL Issue: 2 Date: 21 June 2023
Condition VTOL
Third Publication of Means of Compliance with the Special Condition VTOL
The document at hand, Doc. No. MOC-3 SC-VTOL, contains the third publication of MOCs with the Special Condition VTOL. It proposes a new MOC that adds to the ones already published with Docs. No. MOC SC-VTOL and MOC-2 SC-VTOL.
The first issue of this document was subject to a public consultation on the EASA Comment-Response Tool (CRT) at http://hub.easa.europa.eu/crt/ between 29 June 2022 and 12 August 2022.
It is planned to collect all final MOCs in an upcoming issue of Doc. No. MOC SC-VTOL, for general convenience.
Statement of Issue
Substantial progress has been made in the development and integration of rechargeable lithium batteries in aviation. However, they still represent a significant fire hazard when used as power supply for systems in traditional aircraft due to their susceptibility to failures leading to self-sustaining increases in temperature and pressure (thermal runaway).
The recent use of lithium batteries as propulsion energy storage devices in electric and hybrid aircraft increases the importance of properly addressing this hazard, due to their novel function, higher capacity, higher specific energy, higher voltage, and the lack of significant service experience in this context.
Some of the most common root causes that could lead to a thermal runaway are (non-exhaustive list):
- Design and manufacturing issues. - Installation or maintenance issues. - Internal fault conditions (cell manufacturing quality issues, dendrites…). - External abuse conditions (external short-circuit, overcharge…). - Physical damage during storage, transportation, service, or swapping. - Heat sources (poor electrical connections, corrosion, short-circuits, arcs…).
Some of them can be mitigated through proper adoption of processes throughout design, manufacturing, installation, operation, and maintenance. Others cannot be completely avoided (i.e., cell internal short-circuit due to latent manufacturing defects) and their effect should be mitigated in-service.
Furthermore, the batteries and their protective layers/measures in propulsion battery systems represent a considerable part of the weight of the aircraft. Therefore, it is essential to define test requirements that ensure the adequate level of safety of the product for the intended operational conditions in a feasible way. This may include considerations on the time-to-land following the detection of a thermal runaway.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-3 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source