EASA Certification Specifications with AMC/GMFinal — current published edition checked

CS-23

Normal-Category Aeroplanes

CS Amendment 6; AMC/GM Issue 5 Source checked 2026-11-28

Scope, source and reading notes

Complete Easy Access Rules consolidation of CS-23 Amendment 6 and related AMC/GM Issue 5.

Aerospace Consulting reference note: Current consolidated certification specifications and related compliance guidance for normal-category aeroplanes.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 86ad4923e633b90fc84b90ff5ab4b1caade703896da2ee03657437e1cde181b1

Source page 75 · PDF page 75

AMC2 23.2325 Fire protection

ED Decision 2017/025/R

CS-23 Amdt 4

23.1453 Protection of oxygen equipment from rupture

23.851 Fire extinguishers

23.853 Passenger and crew compartment interiors (With Appendix F)

23.855 Cargo and baggage compartment fire protection (With Appendix F)

23.859(a) Combustion heater fire protection

23.863 Flammable Fluid Fire Protection

23.1337(a) Powerplant instruments installation

23.1351 Electrical system: General

23.1359(a), (c) Electrical System fire protection

23.1383(d) Taxi and landing lights (With Appendix F)

23.1385(d) Position light system installation

AMC3 23.2325 Fire protection

ED Decision 2017/025/R

CS VLA Amdt 1

VLA.853 Passenger and crew compartment interiors (With Appendix F)

VLA.857 Electrical bonding

VLA.863 Flammable Fluid Fire Protection

VLA.1337 Powerplant instruments installation

VLA.1351 Electrical system: General

VLA.1384 External lights

CS 23.2330 Fire protection in designated fire zones

ED Decision 2017/013/R

(a) Flight controls, engine mounts, and other flight structures within or adjacent to designated fire zones must be capable of withstanding the effects of a fire.

(b) A fire in a designated fire zone must not preclude continued safe flight and landing.

(c) Terminals, equipment, and electrical cables used during emergency procedures must be fire- resistant.

AMC1 23.2330 Fire protection in designated fire zones

ED Decision 2026/003/R

ASTM F44 F3264 Standard Specification for Normal Category Aeroplanes Certification

7.7 Fire Protection in Designated Fire Zones and Adjacent Areas

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 23.2010-1

Related technical context

Engineering context
Evidence and scope

AC 23.2010-1 and CS-23 — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.