AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
• Proposed analysis methods;
• Approach for validating the analysis results;
• Pass/fail criteria; and
• Margins (if necessary).
Note: When data have limited substantiation, the analysis plan should also include a description and justification for margins to account for analysis uncertainty. See paragraph 8 for additional information on margins.
9.2.3 Similarity Plan.
A similarity plan should describe the approach undertaken to use the certification data from previously certified systems, equipment, and aircraft in the proposed HIRF compliance program. The similarity plan should include:
• Purpose and scope of the similarity assessment;
• Specific systems addressed by the similarity assessment;
• Data used from the previously certified systems, equipment, and aircraft;
• Details on differences between the aircraft and system being certified and the
similar aircraft and system from which the data will be used; and
• Margins (if necessary).
Note: When data have limited substantiation, the similarity plan should also include a description and justification for margins to account for similarity uncertainty. See paragraph 8 for additional information on margins.
9.3 Compliance Reports.
One or more compliance reports may be necessary to document the results of your test, analysis, or similarity assessments. For new or significantly modified aircraft, HIRF compliance reports include many system and equipment test reports, aircraft test reports, and HIRF vulnerability analysis reports. For these types of HIRF certification programs, a compliance summary report may be useful to summarize the results of tests and analysis. For HIRF certification programs of relatively simple systems, a single compliance report is adequate.
9.3.1 Test Reports.
Comprehensive test reports should be produced at the conclusion of HIRF compliance testing. The test reports should include descriptions of the salient aspects of equipment or system performance during the test, details of any area of noncompliance with HIRF requirements, actions taken to correct the noncompliance, and any similarity declarations. You should also provide supporting rationale for any deviations from system performance observed during testing.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source