AC 20-152A

Development Assurance for Airborne Electronic Hardware

20-152A · 2022-10-07 Source checked 2026-11-28

Scope, source and reading notes

Electronic hardware for type certification or TSO authorisation; objective applicability depends on the hardware and DAL.

Aerospace Consulting reference note: Hardware development assurance, including custom devices, commercial off-the-shelf devices and use of DO-254/ED-80.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 06b17bec98562261063d87e518df3fe581412a5dce64b39ef4769c57433b6bc6

Source page 5 · PDF page 5

5.4 Development Assurance for Simple Custom Devices

For the development of simple custom devices, it is understood that the life cycle data might be significantly reduced compared with the data required for a complex custom device.

ED-80/DO-254 acknowledges that documentation for the design process of a simple hardware device is less extensive than the one needed for a complex device. In addition, while verification and configuration management are also needed, these supporting processes also require less documentation for a simple device. However, it is important that a simple custom device performs its intended function, and is under configuration management, thus allowing the device to be reproduced, conformed, and analyzed to ensure continued operational safety.

Objective CD-2 The applicant should propose a process in the PHAC or any other appropriate planning document to develop simple custom devices that encompasses:

1. Definition of the device functions,

2. Complete verification of the device functions, through tests and analyses,

3. Configuration management of the device, including problem reporting and the instructions to reproduce the device,

4. Assessment of the build conformance of the device.

Sections 5.5.2.4 and 5.5.2.5 of this document also apply to the verification process for simple custom devices.

The life cycle data for simple devices can be combined with other hardware data.

If tools are used for the simple custom device development process, the objectives or clarifications of those objectives described in Section 5.8 of this document are also applicable.

When the applicant intends to reuse a previously developed simple device, ED-80/DO- 254, Section 11.1 and the clarifications provided in Section 5.9 of this document should be used.

If the applicant intends to use COTS IP, the objectives or clarifications of those objectives described in Section 5.11 of this document are also applicable.

5.5 Clarifications to ED-80/DO-254 Validation and Verification Processes

5.5.1 Validation Process

Establishing a correct and complete set of requirements is the cornerstone of the development assurance process. ED-80/DO-254, Section 6.1 addresses the validation process to ensure the completeness and correctness of derived requirements. Nevertheless, the validation process is essential for all the requirements. Indeed, the upper-level requirements allocated to the custom device are often refined, decomposed or restated at the custom device level, and in terms that support the hardware design.

View figures, tables and original page layoutOriginal source page Source page 5 · PDF page 5 of AC 20-152A

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-152A

Related EASA guidance

Engineering context
Evidence and scope

AMC 20-152A §8(b)(1); AC 20-152A §8.3

The AMC cites AC 20-152 without a suffix; the AC cites AMC 20-152(). Pairing these selected editions is editorial.

Comparable subject; no claim of blanket equivalence or automatic mutual acceptance.

Supporting source
EUROCAE ED-80

Recognises this edition

Source-backed
Evidence and scope

AC 20-152A §1, printed p1

Names ED-80, April 2000.

AEH; conditions in AC sections 1 and 2.

Supporting source
RTCA DO-254

Recognises this edition

Source-backed
Evidence and scope

AC 20-152A §1, printed p1

Names DO-254, 19 April 2000.

AEH; conditions in AC sections 1 and 2.

Supporting source
14 CFR 25.1309

Lists related requirement

Source-backed
Evidence and scope

AC 20-152A §8.1, printed p25

Explicitly lists 25.1309 for AEH development assurance.

The source cites the section identifier, without a certification-basis amendment.

Supporting source
AC 25.1309-1B

Referenced by system-safety guidance

Source-backed
Evidence and scope

AC 25.1309-1B §5.3.4.2, printed p5-4 / PDF p30

Identifies AC 20-152A as hardware development-assurance guidance.

Read the source scope and applicable project basis.

Supporting source
ARP4754A

References this edition

Source-backed
Evidence and scope

AC 20-152A §8.4, printed p26

Lists ARP4754A with an explicit date.

Related material; not a replacement for hardware-specific guidance.

Supporting source
ARP4761

References this edition

Source-backed
Evidence and scope

AC 20-152A §8.4, printed p26

Lists ARP4761 with an explicit date.

Related material; not a replacement for hardware-specific guidance.

Supporting source

Copy reference

Select and copy the citation below.