FAA Advisory circularActive — selected source checked

AC 20-152A

Development Assurance for Airborne Electronic Hardware

20-152A · 2022-10-07 Source checked 2026-11-28

Scope, source and reading notes

Electronic hardware for type certification or TSO authorisation; objective applicability depends on the hardware and DAL.

Aerospace Consulting reference note: Hardware development assurance, including custom devices, commercial off-the-shelf devices and use of DO-254/ED-80.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 06b17bec98562261063d87e518df3fe581412a5dce64b39ef4769c57433b6bc6

Source page 23 · PDF page 23

by the applicant, the microcode will not be considered to be part of the qualified COTS device.

Objective COTS-4 If the microcode is not qualified by the device manufacturer or if it is modified by the applicant, the applicant should ensure that a means of compliance for this microcode integrated within the COTS device is proposed by the appropriate process and is commensurate with the usage of the COTS device.

Note: the PHAC (or any other related planning document) should document the existence of the microcode and refer to the process (hardware, software, system) where it is addressed.

6.4.2 COTS Device Malfunctions

Some COTS devices may contain errors that may or may not have been detected by the device manufacturer.

Objective COTS-5 The applicant should assess the errata of the COTS device that are relevant to the use of the device in the intended application and identify and verify the means of mitigation for those errata. If the mitigation means is not implemented in hardware, the mitigation means should be fed back to and verified by the appropriate process.

Note: The above objective refers to any mitigation means (such as hardware, software, system, or other means.)

Objective COTS-6 The applicant should identify the failure modes of the used functions of the device and the possible associated common modes, and feed both of these back to the system safety assessment process.

6.4.3 Usage of COTS Devices

This section focuses on the usage of complex COTS devices, while Section 7 covers the overall circuit board assembly development process. This Section refers to the term “intended function of the hardware,” which is considered to be defined through the CBA development process.

Complex COTS devices can have multiple functions and many configurations of those functions. The configuration of a device should be managed in order to provide the ability to consistently apply the required configuration settings, to replicate the configuration on another item, and to modify the configuration in a controlled manner, when modification is necessary.

The configuration of the device addresses at least the following topics:

• Used functions (e.g., identification of each function, configuration characteristics, modes of operation),

View figures, tables and original page layoutOriginal source page Source page 23 · PDF page 23 of AC 20-152A

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-152A

Related EASA guidance

Engineering context
Evidence and scope

AMC 20-152A §8(b)(1); AC 20-152A §8.3

The AMC cites AC 20-152 without a suffix; the AC cites AMC 20-152(). Pairing these selected editions is editorial.

Comparable subject; no claim of blanket equivalence or automatic mutual acceptance.

Supporting source
EUROCAE ED-80

Recognises this edition

Source-backed
Evidence and scope

AC 20-152A §1, printed p1

Names ED-80, April 2000.

AEH; conditions in AC sections 1 and 2.

Supporting source
RTCA DO-254

Recognises this edition

Source-backed
Evidence and scope

AC 20-152A §1, printed p1

Names DO-254, 19 April 2000.

AEH; conditions in AC sections 1 and 2.

Supporting source
14 CFR 25.1309

Lists related requirement

Source-backed
Evidence and scope

AC 20-152A §8.1, printed p25

Explicitly lists 25.1309 for AEH development assurance.

The source cites the section identifier, without a certification-basis amendment.

Supporting source
AC 25.1309-1B

Referenced by system-safety guidance

Source-backed
Evidence and scope

AC 25.1309-1B §5.3.4.2, printed p5-4 / PDF p30

Identifies AC 20-152A as hardware development-assurance guidance.

Read the source scope and applicable project basis.

Supporting source
ARP4754A

References this edition

Source-backed
Evidence and scope

AC 20-152A §8.4, printed p26

Lists ARP4754A with an explicit date.

Related material; not a replacement for hardware-specific guidance.

Supporting source
ARP4761

References this edition

Source-backed
Evidence and scope

AC 20-152A §8.4, printed p26

Lists ARP4761 with an explicit date.

Related material; not a replacement for hardware-specific guidance.

Supporting source

Copy reference

Select and copy the citation below.