FAA Order 8110.37G
Designated Engineering Representative (DER) Handbook
8110.37G Source checked 2026-11-28
Scope, source and reading notes
FAA procedures and limitations of authority for designated engineering representatives and the FAA staff who manage them; useful to relevant ODA engineering unit members.
Aerospace Consulting reference note: Current DER handbook describing compliance-finding responsibilities, procedures, technical guidance, and limitations of delegated authority.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 57c18cc6c30601537eed2f8e1fc3ff5cad71c5575956de38f0e2b969126e8e41
8110.37G
09/17/2026
(6) Feedback to Foreign Authorities. On some occasions, DERs may conduct certification activities in facilities that hold an approval from their local CAA. The DER may encounter problems during the U.S. project certification activities, such as test failures due to nonconforming test articles or inattention to test plan details. Such experience might be evidence of a system breakdown or a major problem at the facility. If the DER encounters such problems, they must advise the project certification branch and provide details of any problems experienced. The project certification branch will then determine if any systemic issues or major problems should be forwarded to the applicable CAA for its consideration.
11. PMA Identicality Procedures. The FAA requires a DER to follow the provisions of FAA Order 8110.42 when conducting PMA activities. A DER with special delegation for PMA identicality may sign and submit FAA Form 8110-3 without a PSCP or specific prior consent from the FAA. The project certification branch must issue a Letter of Design Approval (LODA) even when a DER is involved in making a finding of identicality.
a. Authority. The managing office must specifically authorize a DER to make PMA identicality findings. The DER and the PMA applicant must verify the DER’s authority and limitations before proceeding with the finding of identicality. The DER must have access to the DAH’s data, allowing for a direct comparison of the design data. Authorized DERs may sign FAA Form 8110-3 as “approved,” indicating identicality to the DAH’s data listed for the TC, STC, TSOA, or letter of TSO design approval (i.e., the data that defines the part covered under a TC, STC, or TSO-approved article as being eligible for installation on a type certified product). The requested eligibility for the applicable product model(s) must be indicated. The DER must send the DAH’s data for the TC, STC, TSOA, or LODA to the project certification branch with FAA Form 8110-3 and PMA data.
b. Findings of Identicality. If a DER checks the approved block on FAA Form 8110-3, it does not mean that the PMA or any engineering aspects of the data are approved. It means the DER is indicating the finding that the PMA applicant’s design is identical to the TC, STC, TSOA, or LODA of the DAH’s design. The DER must append a note in the “List of Data” section stating: “FAA approval of the design is contingent upon FAA engineering verification of the type design data (or STC or TSOA data) listed.”
Note: In the “Purpose of Data” block on FAA Form 8110-3, the DER must state: “Identicality only approval under 14 CFR 21.303.” In the “Applicable Requirements” block, the DER must state: “14 CFR 21.303(a)(4).”
c. FAA Actions. The FAA will verify that the listed DAH’s data for the TC, STC, TSOA, or LODA is approved type design data for the product models indicated, and that the stated eligibility is valid. The FAA will also verify that there are no mandatory corrective actions to be implemented and no serious unresolved service difficulties that make the part ineligible. The applicant’s design does not need to conform to the latest revision level of the DAH’s drawing for the TC, STC, TSOA, or LODA if the FAA determines that the previously approved parts are still eligible for installation on the listed product models. After verifying that all the requirements are met, the project certification branch will continue processing the application in accordance with FAA Order 8110.42.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
FAA Order 8110.4C and FAA Order 8110.37G — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source