FAA Order 8110.37G
Designated Engineering Representative (DER) Handbook
8110.37G Source checked 2026-11-28
Scope, source and reading notes
FAA procedures and limitations of authority for designated engineering representatives and the FAA staff who manage them; useful to relevant ODA engineering unit members.
Aerospace Consulting reference note: Current DER handbook describing compliance-finding responsibilities, procedures, technical guidance, and limitations of delegated authority.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 57c18cc6c30601537eed2f8e1fc3ff5cad71c5575956de38f0e2b969126e8e41
8110.37G
09/17/2026
Certification Plans (PSCPs), determination of test equipment for maintenance, and review of ICA. This review is intended to reduce the FAA’s workload and make the FAA approval (or acceptance) process more efficient for both the applicants and the FAA. Acceptance or approval of such documents must still be accomplished by the FAA. These documents are reviewed for purposes other than finding compliance with airworthiness requirements, so using FAA Form 8110-3 is not appropriate. Instead, these activities should be documented in DMS as “non-8110- 3 activity.”
(3) DER Identification Numbers. DERs are not permitted to use their DER identification number when signing company or personal reports, drawings, service documents, or letters. A DER’s signature on these types of documents does not constitute FAA approval.
k. Separation of Duties. An Organization Designation Authorization (ODA) may identify individuals who are also DERs as Unit Members (UMs). DERs must be aware that the functions they perform as UMs in one of these organizations are separate and distinct from the delegated functions performed as a DER. A DER does not issue FAA Form 8110-3 in support of ODA projects, except when a TC holder’s DER supports a Major Repair, Alteration, and Airworthiness ODA.
l. Coercion. No one may pressure DERs to approve technical data that the DER finds does not comply with the applicable airworthiness requirements or where the DER has not had enough time to review the data. A DER must report any coercion to the project certification branch or managing office, as discussed during the DER appointment and orientation.
2. FAA Form 8110-3, Determination of Compliance with Airworthiness Standards.
a. Using FAA Form 8110-3.
(1) A completed FAA Form 8110-3 is the DER’s only means of approving technical data. This form is used when making or recommending a finding of compliance with airworthiness requirements, according to the DER’s authority.
Note: Although FAA Form 8110-3 is titled “Determination of Compliance with Airworthiness Standards,” it is also used to document a finding of compliance with some regulatory requirements that are not airworthiness standards, such as the requirements for noise, emissions, etc.
(2) FAA Form 8110-3 is used only for documenting a DER’s finding of compliance, and no other purpose. For example, DERs should not use FAA Form 8110-3 to record the disposition of unsatisfactory items found during a conformity inspection.
(3) Generating FAA Form 8110-3. All FAA Form 8110-3s should be initiated in DMS unless doing so is not possible. Refer to FAA Order 8000.95, Volume 9.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
FAA Order 8110.4C and FAA Order 8110.37G — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source