FAA FAA orderActive

FAA Order 8110.112A

Standardized Procedures for Usage of Issue Papers and Development of Equivalent Levels of Safety Memorandums

8110.112A Source checked 2026-11-28

Scope, source and reading notes

FAA internal procedures for issue papers and equivalent-level-of-safety memorandums; this is a process reference, not a collection of project-specific issue papers.

Aerospace Consulting reference note: Standardizes the documentation and resolution of certification issues and development of equivalent-level-of-safety findings, with formats and templates.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 6e48a5cba59de4c4847e9016749ae184817a43ad16627d24cdc7b90474851381

Source page 32 · PDF page 32

10/03/2014 8110.112A Appendix B

1. STATEMENT OF ISSUE: Engine mounts, flight controls, and other flight structure in, or adjacent to, designated fire zones must be fireproof or shielded so that they are capable of withstanding the effects of fire. Fireproof is defined in 14 CFR part 1 as “equivalent to steel.” The engine mount structures on the Generic model airplanes are made of titanium, which may not be equivalent to steel in terms of load-carrying capability at elevated temperatures. Also, some structural components are composed of elastomerics.

2. BACKGROUND: Title 14 CFR 25.865 was added to part 25 by amendment 23 in 1970, although the same requirement had already existed for rotorcraft for many years. Aviation Safety Release No. 415 dated November 9, 1961 states that the component must sustain the loads and perform the function for which it was designed when subjected to a test flame of 2,000 degrees for 15 minutes. This document formed the basis of the current advisory material for transport and utility helicopters (AC 29-2A, Certification of Transport Category Rotorcraft, and AC 27-1, Certification of Normal Category Rotorcraft) and has been used for transport category airplane certification.

Although AC 20-135, Powerplant Installation and Propulsion System Component Fire Protection Test Methods, Standards and Criteria, contains fire protection criteria for powerplants, it does not contain any means of compliance with 14 CFR 25.865. Past programs have generally relied on the criteria in Aviation Safety Release No. 415 although the criteria stated in it are general and subject to varied interpretations. The certification program for the generic model XYZ was delayed because of controversy concerning the means of compliance with 14 CFR 25.865. The following FAA position is developed from the criteria provided in AC 29-2A for transport category rotorcraft, with some modifications appropriate to transport airplanes.

3. FAA POSITION: The titanium and elastomeric structures must be able to sustain the appropriate loads with a positive margin of safety for any foreseeable powerplant fire condition. A test must be performed in which the structures are subjected to a test flame of 2,000 ± 50 degrees for a period of 15 minutes. The heat flux must be as described in AC 20-135, and loads appropriate to the fire condition must be imposed during the test.

In the absence of a more rational determination of the expected flight loads, the structure must be able to support limit flight loads without failure for at least 5 minutes. After 5 minutes and until the end of 15 minutes, the engine may be assumed to be shut down, and the structure must be able to support the discrete source damage loads described in AC 25.571-1A. Freedom from flutter and whirlmode must also be established.

The fail-safe features of the design may be taken into account if it can be shown that foreseeable fire conditions could not affect the integrity of the alternate load paths.

Validated analyses may be used to represent the transient temperature conditions and strength under the applied loads.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 21.101-1B

Related technical context

Engineering context
Evidence and scope

FAA Order 8110.112A and AC 21.101-1B — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.