Means of Compliance with SC-VTOL — Batch 4
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 4 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fourth final batch, introducing further means of compliance and amendments to previous MoC publications.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: d66389491b058ad129efdb1faa6d7d29a1a2bc2bf70dda5612bd6b3f53e2d321
Doc. No: MOC-4 SC-VTOL Issue: 2 Date: 11 July 2025
Fourth Publication of Means of Compliance with the Special Condition VTOL
spacing of structural members, etc.) remain generally the same, the revised analysis could be considered reliable based on the previous validation.
(d) Test only.
Sometimes no reliable analytical method exists, and testing must be used to show compliance with strength and deformation requirements. In other cases, it may be elected to show compliance solely by tests even if there are acceptable analytical methods. In either case, testing by itself can always be used to show compliance with the strength and deformation requirements of SC VTOL Subpart C. In such cases, the test load conditions should be selected to assure all critical design loads are encompassed. If tests only are used to show compliance with strength and deformation requirements for single load path structure which carries flight loads (including pressurisation loads), the test loads must be increased to account for variability in material properties, as required by VTOL.2260 (c). In lieu of a rational analysis, a factor of 1.15 applied to the limit and ultimate flight loads may be used for metallic materials. If the structure has multiple load paths, no material correction factor is required.
Interpretation of Data
(a) The interpretation of the substantiation analysis and test data requires an extensive review of:
the representativeness of the loading; the instrumentation data; comparisons with analytical methods; the representativeness of the test article(s); the test set-up (fixture, load introductions); the load levels and conditions tested; the test results.
(b) Testing is used to validate analytical methods except when showing compliance by test only.
If the test results do not correlate with the analysis, the reasons should be identified and appropriate action taken. This should be accomplished whether or not a test article fails below ultimate load.
(c) Should a failure occur below ultimate load, an investigation should be conducted for the product to reveal the cause of this failure.
This investigation should include a review of the test specimen and loads, analytical loads, and the structural analysis. This may lead to adjustment in analysis/modelling techniques and/or part redesign and may result in the need for additional testing. The need for additional testing to ensure ultimate load capability, depends on the degree to which the failure is understood and the analysis can be validated by the test. The approach described above is valid for static justification. However, a similar approach can be extended for compliance with fatigue, dynamic and crashworthiness requirements. For these applications, the criteria and the classification have to be accepted by and agreed with the authority.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-4 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source