MOC-4 SC-VTOL
Means of Compliance with SC-VTOL — Batch 4
Issue 2 — FINAL Source checked 2026-11-28
Scope, source and reading notes
Complete final batch 4 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.
Aerospace Consulting reference note: Fourth final batch, introducing further means of compliance and amendments to previous MoC publications.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: d66389491b058ad129efdb1faa6d7d29a1a2bc2bf70dda5612bd6b3f53e2d321
Doc. No: MOC-4 SC-VTOL Issue: 2 Date: 11 July 2025
Fourth Publication of Means of Compliance with the Special Condition VTOL
HIRF Groups I and II
(i) For Level A Non-Display Systems:
(A) Follow AMC 20-158A; or (B) Conduct Equipment/System testing using the following default levels:
Conducted susceptibility testing with the Generic transfer function for aircraft (according to VTOL shape and size) extrapolated to the HIRF Environment III (as defined in Section 5) corresponding to the EUROCAE ED-14G section 20 categories Y or W. Radiated Susceptibility testing with Generic attenuation curves (depending on equipment location) extrapolated to the HIRF Environment III (as defined in Section 5) corresponding to the EUROCAE ED-14G section 20 categories L, L-6dB or L-12dB: (…)
MOC VTOL.2525 System power generation, energy storage, and distribution
The following are accepted as means of compliance with VTOL.2525, as applicable:
(a) CS 27.1351 (a), (b), (c) Amdt. 6, Electrical Systems – General
(b) CS 23.1331 (b) Amdt. 4, for instruments using a power source
(c) CS 27.1357 Amdt. 6, for circuit protective devices
(d) To address the hazards associated to the installation of non-propulsion Electrical Storage Devices (ESD):
In normal operation or foreseeable malfunction of the ESD, no explosive, toxic, or corrosive gases or fluids should:
(i) Accumulate in hazardous quantities (ii) Damage structures or adjacent essential equipment or systems (iii) Endanger passengers or crew
Hazardous effects on structures, occupants, essential equipment, or systems caused by the maximum amount of heat that can be generated during normal operation or probable malfunctions should be prevented. The ESD should maintain safe operating temperatures, pressures, or any other identified parameter, during normal operation (including storage, generation/discharging, refilling/recharging and / or jettisoning). The following means of information on the status of the ESD should be established:
(i) When the failure of the ESD could affect safe operation of the aircraft, means to detect the failure and alert the flight crew. (ii) When the ESD is required for the safe operation of the aircraft, means for the flight crew and/or maintenance personnel to determine the ESD charge or status.
The design and installation of the ESD should minimize likely errors during ground handling of the aircraft, the ESD, or its components, to prevent a hazardous event. To that effect:
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
SC-VTOL-02 and MOC-4 SC-VTOL — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.