EASA Means of ComplianceFinal — current published edition checked

MOC-4 SC-VTOL

Means of Compliance with SC-VTOL — Batch 4

Issue 2 — FINAL Source checked 2026-11-28

Scope, source and reading notes

Complete final batch 4 of SC-VTOL means of compliance. Later batches may amend individual provisions in earlier batches.

Aerospace Consulting reference note: Fourth final batch, introducing further means of compliance and amendments to previous MoC publications.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: d66389491b058ad129efdb1faa6d7d29a1a2bc2bf70dda5612bd6b3f53e2d321

Source page 18 · PDF page 18

Doc. No: MOC-4 SC-VTOL Issue: 2 Date: 11 July 2025

Fourth Publication of Means of Compliance with the Special Condition VTOL

Certification Approaches

The following certification approaches may be selected:

(a) Analysis, supported by new strength testing of the structure to limit and ultimate load.

This is typically the certification approach followed for ‘New Structure’. Substantiation of the strength and deformation requirements up to limit and ultimate loads normally requires testing of subcomponents, full scale components or full-scale tests of assembled components (such as a nearly complete airframe). The entire test program should be considered in detail to assure the requirements for strength and deformation can be met up to limit load levels as well as ultimate load levels. Sufficient limit load test conditions should be performed to verify that the structure meets the deformation requirements of VTOL.2235 and to provide validation of internal load distribution and analysis predictions for all critical loading conditions. Because ultimate load tests often result in significant permanent deformation, choices will have to be made with respect to the load conditions applied. This is usually based on the number of test specimens available, the analytical static strength margins of safety of the structure and the range of supporting detail or subcomponent tests. An envelope approach may be taken, where a combination of different load cases is applied, each one critical for a different section of the structure. These limit and ultimate load tests may be supported by detail and subcomponent tests that verify the design allowables (tension, shear, compression) of the structure and often provide some degree of validation for ultimate strength.

(b) Analysis validated by previous test evidence and supported with additional limited testing.

This is typically the certification approach followed for ‘Similar New Structure’. The extent of additional limited testing (number of specimens, load levels, etc.) will depend upon the degree of change, relative to the elements of paragraphs 4.(b)(1) and (2). For example, if the changes to an existing design and analysis necessitate extensive changes to an existing test-validated finite element model (e.g. different rib spacing) additional testing may be needed. Previous test evidence can be relied upon whenever practical. Additional limited tests may be further supported by detail and subcomponent tests that verify the design allowables (tension, shear, compression) of the structure, and often provide some degree of validation for ultimate strength.

(c) Analysis, supported by previous test evidence.

This is typically the certification approach followed for Derivative/ Similar Structure. Justification should be provided for this approach by demonstrating how the previous static test evidence validates the analysis and supports showing compliance for the structure under investigation. Elements that need to be considered are those defined in paragraphs 4. (b)(1) and (2). For example, if the changes to the existing design and test-validated analysis are evaluated to assure they are relatively minor and the effects of the changes are well understood, the original tests may provide sufficient validation of the analysis and further testing may not be necessary. As an illustration of this general example, in a case where a mass increase results in higher loads, along with a corresponding increase in some of the element thickness and fastener sizes, while the materials and geometry (overall configuration,

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

SC-VTOL-02

Related technical context

Engineering context
Evidence and scope

SC-VTOL-02 and MOC-4 SC-VTOL — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.