Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems, including all three appendices.
Aerospace Consulting reference note: Provides the HIRF protection framework and supporting environmental, transfer-function and safety-assessment guidance.
Complete selected AMC and associated material, from PDF pages 518–559 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a
Table 3: HIRF Environment II
FREQUENCY FIELD STRENGTH (V/m) PEAK AVERAGE 10–500 kHz 20 20 500 kHz–2 MHz 30 30 2–30 MHz 100 100 30–100 MHz 10 10 100–200 MHz 30 10 200–400 MHz 10 10 400 MHz–1 GHz 700 40 1–2 GHz 1 300 160 2–4 GHz 3 000 120 4–6 GHz 3 000 160 6–8 GHz 400 170 8–12 GHz 1 230 230 12–18 GHz 730 190 18–40 GHz 600 150
In this table, the higher field strength applies at the frequency band edges.
Table 4: HIRF Environment III
FREQUENCY FIELD STRENGTH (V/m) PEAK AVERAGE 10–100 kHz 150 150 100 kHz–400 MHz 200 200 400–700 MHz 730 200 700 MHz–1 GHz 1 400 240 1–2 GHz 5 000 250 2–4 GHz 6 000 490 4–6 GHz 7 200 400 6–8 GHz 1 100 170 8–12 GHz 5 000 330 12–18 GHz 2 000 330 18–40 GHz 1 000 420
In this table, the higher field strength applies at the frequency band edges.
d. Establish the test environment for installed systems
1. General. The external HIRF environment will penetrate the aircraft and establish an internal RF environment to which installed electrical and electronic systems will be exposed. The resultant internal RF environment is caused by a combination of factors, such as aircraft seams and apertures, reradiation from the internal aircraft structure and wiring, and characteristic aircraft electrical resonance.
2. Level A systems. The resulting internal HIRF environments for Level A systems are determined by aircraft attenuation of external HIRF Environment I, II, or III, as defined in CS-23 Appendix K, in CS-25 Appendix R, in CS-27 Appendix D, and in CS- 29 Appendix E, as applicable. The attenuation is aircraft- and zone-specific and should be established by aircraft test, analysis, or similarity. The steps for showing Level A HIRF compliance are presented in Section 8 of this AMC.
View figures, tables and original page layout

Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.