AMC 20-158A
Aircraft electrical and electronic system high-intensity radiated fields (HIRF) protection
Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems, including all three appendices.
Aerospace Consulting reference note: Provides the HIRF protection framework and supporting environmental, transfer-function and safety-assessment guidance.
Complete selected AMC and associated material, from PDF pages 518–559 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a
Appendix 3 to AMC 20-158A — Examples of HIRF safety assessment considerations — Level A systems on large aeroplanes
ED Decision 2022/001/R
1. Establishing appropriate pass/fail criteria for complying with CS 25.1317(a) can only be achieved through a comprehensive review of the system design using an acceptable HIRF functional hazard assessment process in the form of a system HIRF certification level (HCL). The following paragraphs summarise the approaches whereby pass/fail criteria for compliance with CS 25.1317(a) are specified on the merit of specific system architecture attributes.
2. For the purposes of discussion and evaluation of the examples, the architectural strategies used in the system implementation need to be defined. Therefore, the additional definitions below should be considered:
a. Similar redundant channels: the multiple channels consist of equipment, components, electrical interconnections and configurations that are similar, typically with pieces of equipment that have identical part numbers. The channels should be independent. They may be configured in active, active-backup and passive-backup modes.
b. Dissimilar redundant channels: each channel is unique and independent of the others. They may be configured in active, active-backup and passive-backup modes.
c. Combination of similar and dissimilar redundant channels: the combination of similar and dissimilar channels, as defined above, with independence between channels. They may be configured in active, active-backup and passive-backup modes.
Notes:
a. ‘Active mode’ means that the channel performs the aircraft function in normal operation.
b. ‘Active-backup mode’ means that the channel is operational but not used to perform the aircraft function until switched to active mode either automatically or by flight crew action.
c. ‘Passive-backup mode’ means that the channel is not operational; switching to active mode is either automatic or by flight crew action upon failure recognition.
d. ‘Combination of electrical/electronic and mechanical, hydraulic and/or pneumatic channels’: certain architectures combine electrical and electronic channels with mechanical, hydraulic and/or pneumatic channels. These combinations of electrical/electronic and mechanical, hydraulic or pneumatic channels may be configured in active, active-backup and passive-backup modes.
e. These examples are theoretical and intended to facilitate the discussion from which universal guidelines may be derived to help develop useful guidance material. It is not the intention to account for all possible configurations but only to represent the common system architectures or some that present unique challenges.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source