EASA Acceptable Means of ComplianceFinal — current published edition checked

AMC 20-158A

Aircraft electrical and electronic system high-intensity radiated fields (HIRF) protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems, including all three appendices.

Aerospace Consulting reference note: Provides the HIRF protection framework and supporting environmental, transfer-function and safety-assessment guidance.

Complete selected AMC and associated material, from PDF pages 518–559 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 553 · PDF page 553

c. Different attenuation values may be appropriate for different frequency ranges. For example, 0 dB attenuation may be used for the frequency range of 100 to 400 MHz, 6 dB attenuation for the frequency range of 400 MHz to 1 GHz, and 12 dB attenuation for the frequency range of 1 to 18 GHz. If an applicant intends to use different attenuation values for various frequency ranges, then they should also provide the supporting rationale.

d. Consult the User’s Guide (SAE ARP 5583A / EUROCAE ED-107A) for details on the use of generic attenuation.

3. Measured transfer functions or attenuation

The applicant may produce their own generic transfer functions and attenuation for their Level A display systems (see Section 9(k)) based on actual measurements on their aircraft models. These transfer functions and the attenuation can then be used in their HIRF compliance submission in place of the generic transfer functions and attenuation specified in this Appendix. The Agency encourages this approach because it provides a more accurate reflection of the true internal HIRF environment for aircraft models. However, if an applicant intends to produce their own generic transfer functions and attenuation, then this approach should also be addressed in the HIRF compliance plan (see Section 6(a)) that is submitted to the Agency for acceptance.

Figure A1-6: Generic attenuation values — All aircraft

100 MHz to 18 GHz

[Amdt 20/23]

View figures, tables and original page layoutOriginal source page Source page 553 · PDF page 553 of AMC 20-158A

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-158B

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.