FAA Advisory circularActive

AC 21-16G

RTCA Document DO-160 Versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment

21-16G Source checked 2026-11-28

Scope, source and reading notes

FAA recognition of DO-160 versions D, E, F, and G for environmental qualification of airborne equipment; this public AC does not reproduce the licensed DO-160 standard.

Aerospace Consulting reference note: Identifies acceptable DO-160 environmental qualification versions and explains differences between versions; encourages DO-160G for new articles.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 9cc0d157c556014fb13676330a3bf3d2732d6fd35786a59bd39880acc78c7871

Source page 14 · PDF page 14

requirements portion adds the test methods and test levels for performing Waveform 6 Multiple Burst testing. Voltage limits for Waveform 6 are based on the open circuit voltage level from Waveform 3 Pin Injection, as Waveform 6, by definition, does not have a voltage limit. The Waveform 6 Multiple Burst test resulted in the addition of another waveform set character to identify the waveform used for Multiple Burst testing. Waveform set ‘L’ is used to identify Waveform 3 Multiple Burst and waveform set ‘M’ identifies Waveform 6 Multiple Burst.

Due to potential inconsistencies between the two Pin Injection test calibration methods, the resistor method was removed. The open circuit voltage/short circuit current method is considered the preferred method. As a result of the method elimination, several test setup diagrams were updated to reflect the change.

Clarification was added for the use of the ‘Z’ designator when the waveform generator is switched because the generator used did not produce a compliant ‘limit’ waveform. It is now specified that switching generators requires that the waveform set designation be a ‘Z’, the only exception being where

A-10

DO-160 Sections Changes from DO-160C to DO-160D1 Changes from DO-160D1 to DO-160E Changes from DO-160E to DO-160F Changes from DO-160F to DO-160G

06/22/2011 AC 21-16G Appendix 1

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-190

Related technical context

Engineering context
Evidence and scope

AC 21-16G and AC 20-190 — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.