AC 21-16G
RTCA Document DO-160 Versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment
21-16G Source checked 2026-11-28
Scope, source and reading notes
FAA recognition of DO-160 versions D, E, F, and G for environmental qualification of airborne equipment; this public AC does not reproduce the licensed DO-160 standard.
Aerospace Consulting reference note: Identifies acceptable DO-160 environmental qualification versions and explains differences between versions; encourages DO-160G for new articles.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 9cc0d157c556014fb13676330a3bf3d2732d6fd35786a59bd39880acc78c7871
this is done for power line testing only. Testing of the power line separate from a standard interconnect bundle is the most common way of testing, therefore the exception is allowed providing better representation of the waveform set used for testing on the EUT interconnect bundle.
No changes were made.
No changes were made.
A-11
No significant changes were made. Clarification of test waveforms and methods has been added throughout the section. Category designations have been added to separate voltage and current tests. Category designations have been clarified, and Category F was deleted.
Additional procedure with associated electrode was provided for producing flashover when flashover is not produced during the normal procedure and it is desired that flashovers occur.
DO-160 Sections Changes from DO-160C to DO-160D1 Changes from DO-160D1 to DO-160E Changes from DO-160E to DO-160F Changes from DO-160F to DO-160G
Section 24: Icing Editorial and clarifications changes only. No changes were made. No major changes were made. Clarification of type of ice was incorporated.
Section 25: A new section was added to No significant changes were No significant changes were Added note that ESD connection
Electrostatic address device level made. made, except correcting point is not applicable to connector
Discharge susceptibility issues for ESD. typographical errors in the figures. pins. Added expansion of type and of the list of test points to be considered. Address case of no discharge.
Section 26: Section 26 was introduced in No changes were made. Categories A and B minor wording
Fire, DO-160E. changes, test method remained the
Flammability same. Category C: Flammability Entire section removed and replaced with FAA accepted methods verbatim from FAA Fire Test Handbook. Added configurations exempt from testing. Added definitions for “small parts exemption”. Added user guide
06/22/2011 AC 21-16G Appendix 1
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 21-16G and AC 20-190 — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source