FAA Advisory circularActive

AC 21-16G

RTCA Document DO-160 Versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment

21-16G Source checked 2026-11-28

Scope, source and reading notes

FAA recognition of DO-160 versions D, E, F, and G for environmental qualification of airborne equipment; this public AC does not reproduce the licensed DO-160 standard.

Aerospace Consulting reference note: Identifies acceptable DO-160 environmental qualification versions and explains differences between versions; encourages DO-160G for new articles.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 9cc0d157c556014fb13676330a3bf3d2732d6fd35786a59bd39880acc78c7871

Source page 6 · PDF page 6

control. Paragraphs 5.3.1a and d – added clarification of temperature change procedure for Operating Low and Operating High Temperatures.

operating, and its temperature stabilized. Apply to the test item three shocks having a terminal saw­

tooth wave shape with an acceleration peak value of six (6) g's in each orientation."

6.3, removed word hydroxide.

performance compliance timing to be in the second, or last cycle.

in the note clarified cooling source and power.

6.3.3 changed step 2 to 38 degrees to agree with corresponding figure.

A-2

shock tests, categories S1 and S2, and Sections 5.3.2 and 5.3.3 are the tests sections that accompany the newly added categories, respectively.

same. definitions were revised in section 7.3.3 and figure 7.3, respectively, to reflect the correct setup direction for acceleration load.

allow a + 4 percent tolerance to the relative humidity requirement.

160C based on empirical data.

DO-160 Sections Changes from DO-160C to DO-160D1 Changes from DO-160D1 to DO-160E Changes from DO-160E to DO-160F Changes from DO-160F to DO-160G

Section 5: Section 5.3 Test Procedures Section 5.2 Temperature Change Sections, 5.3.1h, 5.3.2h, and Paragraph 5.1 – Added note

Temperature was revised to provide Rates added two temperature 5.3.3i, changed the clarifying test intent and humidity

Variation provisions for collecting data during a single cycle of test and reduced data collection under certain test conditions.

Section 6: Editorial changes were made Section 6.3 was modified to In paragraphs 6.3.1, 6.3.2, and Corrected terminology paragraph

Humidity to eliminate redundant description of the test procedures. Velocity of air throughout the exposure area changed from “Shall not exceed 0.75 m/s” to “Between 0.5 and 1.7 m/s”. Alternative method was added to measure the water pH.

Section 7: Equipment category Fixed wing and helicopter Category definitions were Added in Section 7.2.1 “Unless

Operational definitions were added for operational and crash safety test revised for clarification. Text otherwise stated in the EUT

Shocks and fixed wing and helicopter requirements were made the description and centrifuge specification, the equipment shall be

Crash Safety installations. Crash Safety levels were identified for helicopters (20g) and increased for fixed wing crash safety levels (20g). Shock pulse was changed from half sine to saw tooth. Half-sine shock pulse curve changed to reflect saw-tooth profile. Test levels were changed from DO­

06/22/2011 AC 21-16G Appendix 1

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-190

Related technical context

Engineering context
Evidence and scope

AC 21-16G and AC 20-190 — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.