AC 21-16G
RTCA Document DO-160 Versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment
21-16G Source checked 2026-11-28
Scope, source and reading notes
FAA recognition of DO-160 versions D, E, F, and G for environmental qualification of airborne equipment; this public AC does not reproduce the licensed DO-160 standard.
Aerospace Consulting reference note: Identifies acceptable DO-160 environmental qualification versions and explains differences between versions; encourages DO-160G for new articles.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 9cc0d157c556014fb13676330a3bf3d2732d6fd35786a59bd39880acc78c7871
Category Q definition. Inserted two new Figures for Category Q, Fig. 21-4 and Fig. 21-5. Renumbered remaining figures as required. Added Section 21 User Guide to Section 21.
appendix removes guidance material from the requirements portion of the section. This allows for an in-depth discussion on relevant topics without “muddying” the procedures and test level definitions contained in the requirements portion of Section 22. The UG format is a paragraph by paragraph match with the requirements section for easy references to guidance on specific topics. Where no guidance material was added, the UG paragraph is not populated. It is expected that the UG will assist equipment designers with design and test considerations as well as improve standardization of testing between test facilities. For example, by providing a detailed discussion on dealing with noise during waveform measurements, labs are more likely to use the same methodology for making measurements, resulting in much more consistency across the industry.
The DO-160G Section 22
body of the document, and paragraphs were numbered to provide easy reference to the requirements contained in each paragraph. In the waveform set tables and the test level tables, both the voltage and the current waveform number are now shown to eliminate any ambiguities with how waveforms are related to each other. This section was modified to clarify when a test was successfully completed and when, in the case of reaching a limiting level before a test level, another waveform test was needed. The cable bundle section now contains a path to follow for every waveform set and criteria for acceptable and unacceptable test limit waveforms that leads the user to successful test completion regardless of the configuration of the cable under test.
A-9
bundle tests on bundles that normally contain shields, with the shields removed. This guidance allowed testing of a cable bundle at test levels currently defined in DO-160, but intended to demonstrate compliance to aircraft installation threats that are higher than these standardized levels. It explicitly stated that the test generator used for cable bundle testing does not need to be capable of producing the voltage or current limit level, provided that the current or voltage test level can be achieved on the cable under test.
DO-160 Sections Changes from DO-160C to DO-160D1 Changes from DO-160D1 to DO-160E Changes from DO-160E to DO-160F Changes from DO-160F to DO-160G
Section 22: DO-160D Change No. 3, The DO-160E cable bundle test Section 22 was restructured The most significant change to
Lightning published December 2002, section was modified to include with additional test Section 22 in DO-160G is the
Induced added additional waveform a new section providing requirements moved from addition of a User’s Guide (UG) as
Transient sets, cable bundle test levels, guidance for performing cable notes under figures to the main an appendix to Section 22. This
Susceptibility and the procedures for performing indirect lightning multiple stroke and multiple burst tests using the existing defined test waveforms. The category designations were modified to allow users to designate categories that indicated that these additional tests had been performed. New Waveform Set designators, G through K, were added to cover the Multiple Burst and Multiple Stroke tests. Another significant addition to Change 3 was setup information on performing pin injection tests with power applied. Several different setup diagrams were added to assist users in performing these tests properly. Improperly connecting the lightning generator to a pin with power applied could result in insufficient stress on the pin.
06/22/2011 AC 21-16G Appendix 1
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 21-16G and AC 20-190 — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source