FAA Advisory circularActive

AC 20-158B

The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment

20-158B Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.

Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3

Source page 39 · PDF page 39

10.13.2 If the conducted RF susceptibility test levels used for the integrated system test (see step

5) were too low when compared with the aircraft-induced currents determined in step 10b, 10c, 11, or 12, then corrective measures are needed (see step 14). If the radiated RF susceptibility test levels used for integrated system tests (see step 5) were too low when compared with the aircraft internal fields determined in step 10d, 11, or 12, then corrective measures are needed (see step 14).

10.13.3 When comparing the current measured during low-level swept-current tests in step 10c

with the current used during the integrated system tests in step 5, there may be differences. These differences may be due to variations between the actual aircraft installation and the laboratory integrated system test installation, such as wire bundle lengths, shielding and bonding, and wire bundle composition. The worst-case current signature for a particular wire bundle should be compared to the current induced at the particular test level or equipment malfunction over discrete frequency ranges such as 50 kHz to 500 kHz, 500 kHz to 30 MHz, and 30 MHz to 100 MHz. This comparison should be broken into discrete frequency ranges because the resonant frequencies may differ between the integrated system tests and the aircraft tests.

If you used aircraft high-level tests (see step 9) for aircraft HIRF verification, you should determine if there were any level A system susceptibilities. Any level A system susceptibilities should be evaluated based on the pass/fail criteria as established in the HIRF test plan (see paragraph 9.2.1). If the HIRF susceptibilities are not acceptable, then corrective measures may be needed (see step 14).

10.13.4 HIRF susceptibilities that were not anticipated or defined in the test plan pass/fail

criteria may be observed during aircraft high-level tests or laboratory integrated system tests.

10.13.5 The pass/fail criteria may be modified if the effects neither cause nor contribute to

conditions that adversely affect the aircraft functions or systems in the HIRF regulations. You should provide an assessment and supporting rationale for any modifications to the pass/fail criteria to the FAA for approval. If the HIRF susceptibilities are not acceptable, then corrective measures may be needed (see step 14).

10.13.6 If the level A systems show no adverse effects when tested to levels derived from the

applicable HIRF environment I or III, this also demonstrates compliance of the system with HIRF environment II.

10.13.7 If the integrated system tests results (see step 5) satisfy the pass criteria from 12 GHz to

18 GHz, and design analysis shows the system has no circuits operating in the 18 GHz to 40 GHz frequency range, this demonstrates by analysis the system is not adversely affected when exposed to HIRF environments above 18 GHz. If these conditions are satisfied, further aircraft and system tests and assessments above 18 GHz are not necessary.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-158A

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.