FAA Advisory circularActive

AC 20-158B

The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment

20-158B Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.

Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3

Source page 32 · PDF page 32

10.5.11 If the level A system consists of multiple similar channels, you may propose using one

or more channels in the laboratory test setup for the integrated system, instead of all similar channels. You should demonstrate that the laboratory test setup adequately performs the functions to demonstrate compliance with §§ 23.1308(a), 23.2520(a), 25.1317(a), 27.1317(a), or § 29.1317(a). Ensure that the laboratory test setup represents and monitors any cross-channel interactions, such as cross-channel data links, redundancy management, and system health monitoring.

Note: If pin programming or software is used to identify or configure equipment of similar elements or channels, you should assess whether these differences impact the functions performed.

10.6 Step 6 — System Similarity Assessment.

10.6.1 The integrated system HIRF tests performed for a system previously certified on one aircraft model may be used to demonstrate system verification for a similar system. Each system considered under the similarity approach needs to be assessed independently even if it may use equipment and installation techniques from previous certification projects.

10.6.2 The system used as the basis for similarity must have successfully completed integrated system HIRF tests. Similarity assessment requires comparison of both equipment and installation differences that could adversely affect HIRF immunity. The assessment should evaluate the differences between the previously HIRF-certified system and the equipment circuit interfaces, wiring, grounding, bonding, connectors, and wire- shielding practices of the equipment that comprise the new system.

10.6.3 If the assessment finds negligible differences, with respect to HIRF aspects, between the previously certified system and the new system to be certified, similarity may be used as the basis for system-level verification without the need for additional integrated system tests, providing there are no unresolved in-service HIRF problems related to the previously certified system. If there is uncertainty about the effects of the differences, additional tests and analysis should be conducted as necessary and appropriate to resolve the uncertainty. The amount of additional testing should be commensurate with the degree of difference identified between the new system and the system previously certified. If significant differences are found, similarity should not be used as the basis for system-level verification.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-158A

Related technical context

Engineering context