AC 20-158B
The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment
20-158B Source checked 2026-11-28
Scope, source and reading notes
HIRF protection for aircraft electrical and electronic systems where the certification basis includes the specified Part 23, 25, 27, or 29 requirements.
Aerospace Consulting reference note: Guidance for demonstrating that aircraft electrical and electronic systems are protected against the high-intensity radiated fields environment.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: c3be1c8b9e84592a978a2be6c3b8f89abfa59a6430af80afdacee892c3c917d3
You should perform a safety assessment related to HIRF to establish and classify the equipment or system failure condition. Table 1 provides the corresponding failure condition classification and system HIRF certification level (HCL) for the appropriate HIRF regulations. The failure condition classifications and terms used in this AC are like those used in AC 23.1309-1, AC 25.1309-1, AC-27-1, and AC-29-2, as applicable. Only those systems identified as performing or contributing to functions whose failure would result in catastrophic, hazardous, or major failure conditions are subject to HIRF regulations. Based on the failure condition classification established by the safety assessment, the systems should be assigned appropriate HCLs, as shown in table 1. The safety assessment should consider the common cause effects of HIRF, particularly for highly integrated systems and systems with redundant elements. The HIRF safety assessment determines the consequences of failures for the aircraft functions that are performed by the system.
7.3.1 HCL Classification The HCL classification assigned to the system and functions may be different from the design assurance level assigned for equipment redundancy, software, and complex electronic hardware. This is because HIRF environments can cause common cause effects. The term “design assurance level” should not be used to describe the HCL because of the potential differences in assigned classifications for software, complex electronic hardware, and equipment redundancy. The HIRF safety assessment should include all electrical and electronic equipment, components, and electrical interconnections, and should assume that they are potentially affected by HIRF. It is not appropriate to use the HIRF immunity data for electrical and electronic equipment, components, and electrical interconnections as input information on the HIRF safety assessment. This information should only be used in the next phase activity in the section below to show compliance with the applicable paragraph of the HIRF regulations, after the required HCL for the system is determined by the HIRF safety assessment. The HIRF safety assessment should have input from and be coordinated between the applicant’s safety specialists, system specialists, and HIRF specialists. This process may vary from applicant to applicant. Further guidance on performing the safety assessment can be found in AC 23.1309-1, AC 25.1309-1, AC-27-1, AC-29-2, SAE ARP4754A, SAE ARP4761, and SAE ARP5583A.
Note: Considering that HIRF and lightning environments may have similar effects on electronic systems (disturbing electrical signals causing upsets or damage to circuits) and that the regulations for each are similarly structured, the system HCL and lightning certification level may be the same.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 20-158B and AMC 20-158A — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source