AMC 20-152A
Development Assurance for Airborne Electronic Hardware (AEH)
AMC 20-152A · introduced by Amendment 19; consolidated in AMC-20 Amendment 23 Source checked 2026-11-28
Scope, source and reading notes
Hardware development assurance for airborne electronic hardware, including custom devices and commercial off-the-shelf devices.
Aerospace Consulting reference note: Explains EASA expectations for airborne electronic hardware development assurance and the use of ED-80/DO-254. Includes the complete current AMC in the Amendment 23 consolidation.
Complete selected AMC and associated material, from PDF pages 497–517 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a
5.7 Recognition of HDL Code Coverage Method
HDL code coverage analysis is an assessment of whether the HDL code of the design has been exercised through HDL simulations.
The HDL code coverage method provides an assessment of the coverage of the design logic structure, giving an indication of which aspects of the logic structure are exercised and which are not.
When performed during requirements-based verification (per ED-80/DO-254 Section 6.2), HDL code coverage is recognised as a method to perform ED-80/DO-254 elemental analysis per Appendix B Section 3.3.1 for digital devices. HDL code coverage supports the assessment of whether the HDL code elements are fully covered by requirements-based simulations. As such, it does not represent an assessment of the completeness of the requirements-based testing activities or the effectiveness of the requirement coverage.
Objective CD-9
For hardware DAL A or DAL B, where HDL code coverage is used to perform elemental analysis (ED- 80/DO-254 Appendix B Section 3.3.1), the applicant should define in the planning documents the detailed coverage criteria of the HDL code elements used in the design. The criteria should ensure coverage over the various cases of the HDL code elements used in the design (e.g. branches, conditions, etc.). Any non-covered case or element should be analysed and justified.
Note: Code coverage might need to be complemented by additional analysis for any hardware items that are identified as not covered by the code coverage analysis, in order to complete the elemental analysis of all elements. This situation may occur in the use of some COTS IP instantiations.
5.8 Clarifications to ED-80/DO-254 ‘Tool Assessment and Qualification’
ED-80/DO-254 introduces the notion of tool assessment and qualification. ED-80/DO-254 Figure 11-1 includes a flow chart indicating the tool assessment considerations and activities, and provides guidance for when tool qualification may be necessary. This AMC uses the flow chart and its related text as a basis for providing further clarification, as follows:
ED-80/DO-254 — Figure 11-1 Item 1 — Identify the Tool
Information capturing the environment required for tool operation and the tool revision should be included with the tool identification.
ED-80/DO-254 — Figure 11-1 Item 2 — Identify the Process the Tool Supports
When identifying the design or verification process that the tool supports, it is important to also identify what purpose or activity within the hardware development process the tool satisfies. While assessing the tool limitations, evidence of formal assessment of the tool problem reports is not required if the tool output has been completely and independently assessed.
ED-80/DO-254 — Figure 11-1 Item 3 — Is the Tool Output Independently Assessed?
The purpose of assessing the tool output is to completely cover, with an independent means, the potential errors that the tool could introduce into the design or fail to detect during verification.
Objective CD-10
When the applicant intends to independently assess a tool output, the applicant should propose an independent assessment that verifies the tool output is correct. The independent assessment should justify that there is sufficient coverage of the tool output. The completeness of the tool assessment should be based on the design/implementation and/or verification objectives that the tool is used to satisfy.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Recognises this edition
Source-backedEvidence and scope
AMC 20-152A §1.2
Names ED-80, April 2000.
AEH; AMC applicability and supplementary objectives remain relevant.
Supporting sourceRecognises this edition
Source-backedEvidence and scope
AMC 20-152A §1.2
Names DO-254, 19 April 2000.
AEH; AMC applicability and supplementary objectives remain relevant.
Supporting sourceReferenced by AMC 25.1309
Source-backedEvidence and scope
EASA CS-25 Amendment 28 consolidated publication AMC 25.1309 §3(a)(5), p858; EASA CS 25 Amendment28 change information AMC 25.1309 §3(a)(5), p88
Explicitly references AMC 20-152A for airborne electronic hardware assurance. Corroborates the addition/reference of AMC 20-152A; change markup must not be presented as consolidated source text.
Read the cited document’s applicability and the project certification basis.
Supporting sourceLists this CS family
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting sourceRelated FAA guidance
Engineering contextEvidence and scope
AMC 20-152A §8(b)(1); AC 20-152A §8.3
The AMC cites AC 20-152 without a suffix; the AC cites AMC 20-152(). Pairing these selected editions is editorial.
Comparable subject; no claim of blanket equivalence or automatic mutual acceptance.
Supporting sourceReferenced by memorandum
Source-backedEvidence and scope
EASA CM-DASA-002 Issue 01 FINAL §1.1, p5
Item-level software/hardware and the safety-assessment process itself are excluded; AMC 20-115D and AMC 20-152A are referenced. Safety-process interfaces remain in scope.
Read the cited document’s applicability and the project certification basis.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(4)
Lists ARP4754A with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(1)
Lists ED-79A with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(5)
Lists ARP4761 with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting source