AMC 20-152A
Development Assurance for Airborne Electronic Hardware (AEH)
AMC 20-152A · introduced by Amendment 19; consolidated in AMC-20 Amendment 23 Source checked 2026-11-28
Scope, source and reading notes
Hardware development assurance for airborne electronic hardware, including custom devices and commercial off-the-shelf devices.
Aerospace Consulting reference note: Explains EASA expectations for airborne electronic hardware development assurance and the use of ED-80/DO-254. Includes the complete current AMC in the Amendment 23 consolidation.
Complete selected AMC and associated material, from PDF pages 497–517 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a
supplement ED-80/DO-254 Section 11.2 in clarifying how to gain certification credit when using complex COTS devices.
6.4.1 Electronic Component Management Process (ECMP)
As stated in ED-80/DO-254 Section 11.2, ‘the use of an electronic component management process, in conjunction with the design process, provides the basis for COTS components usage.’
Objective COTS-2
The applicant should ensure that an electronic component management process (ECMP) exists to address the selection, qualification, and configuration management of COTS devices. The ECMP should also address the access to component data such as the user manual, the datasheet, errata, installation manual, and access to information on changes made by the component manufacturer.
As part of the ECMP, for devices contributing to hardware DAL A or B functions, the process for selecting a complex COTS device should consider the maturity of the COTS device and, where risks are identified, they should be appropriately mitigated.
Note: Recognised industry standards describing the principles of electronic component management may be used to support the development of the ECMP. See Appendix B.
6.4.1.1 Using a Device outside Ranges of Values Specified in its Datasheet
The device reliability is established by the device manufacturer through the device qualification process (see definition of ‘qualification of a device’ in the glossary). ED-80/DO254 Section 11.2.1 Item 6 mentions that a device is selected based on the technical suitability of the device for the intended application.
In some cases, the applicant may need to use the device outside the specified operating conditions guaranteed by the device manufacturer. ED-80/DO-254 Section 11.2.1 Item 4 and Item 6 should be addressed when the device is used outside its guaranteed specification. The following objective describes what to achieve when using a device outside the ranges of values specified in its datasheet.
Objective COTS-3
When the complex COTS device is used outside the limits of the device manufacturer’s specification (such as the recommended operating limits), the applicant should establish the reliability and the technical suitability of the device in the intended application.
6.4.1.2 Considerations when the COTS Device has Embedded Microcode
COTS devices may need microcode to execute some hardware functions. When those functions are used by the applicant, there is a risk if the microcode has not been verified by the device manufacturer during the COTS device qualification, or if the microcode is proposed to be modified by the applicant.
If the microcode is delivered by the device manufacturer, is controlled by the device manufacturer’s configuration management system, and is qualified together with the device by the device manufacturer, it is accepted that the microcode is part of the qualified COTS device. If the microcode is not qualified by the device manufacturer or if it is modified by the applicant, the microcode cannot be considered to be part of the qualified COTS device.
Objective COTS-4
If the microcode is not qualified by the device manufacturer or if it is modified by the applicant, the applicant should ensure that a means of compliance for this microcode integrated within the COTS device is proposed by the appropriate process, and is commensurate with the usage of the COTS device.
Note: The PHAC (or any other related planning document) should document the existence of the microcode and refer to the process (hardware, software, system) where it is addressed.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Recognises this edition
Source-backedEvidence and scope
AMC 20-152A §1.2
Names ED-80, April 2000.
AEH; AMC applicability and supplementary objectives remain relevant.
Supporting sourceRecognises this edition
Source-backedEvidence and scope
AMC 20-152A §1.2
Names DO-254, 19 April 2000.
AEH; AMC applicability and supplementary objectives remain relevant.
Supporting sourceReferenced by AMC 25.1309
Source-backedEvidence and scope
EASA CS-25 Amendment 28 consolidated publication AMC 25.1309 §3(a)(5), p858; EASA CS 25 Amendment28 change information AMC 25.1309 §3(a)(5), p88
Explicitly references AMC 20-152A for airborne electronic hardware assurance. Corroborates the addition/reference of AMC 20-152A; change markup must not be presented as consolidated source text.
Read the cited document’s applicability and the project certification basis.
Supporting sourceLists this CS family
Source-backedEvidence and scope
AMC 20-152A §8(a)(2)
Lists CS-25 without an amendment or specific paragraph.
Family reference; does not select a certification basis.
Supporting sourceRelated FAA guidance
Engineering contextEvidence and scope
AMC 20-152A §8(b)(1); AC 20-152A §8.3
The AMC cites AC 20-152 without a suffix; the AC cites AMC 20-152(). Pairing these selected editions is editorial.
Comparable subject; no claim of blanket equivalence or automatic mutual acceptance.
Supporting sourceReferenced by memorandum
Source-backedEvidence and scope
EASA CM-DASA-002 Issue 01 FINAL §1.1, p5
Item-level software/hardware and the safety-assessment process itself are excluded; AMC 20-115D and AMC 20-152A are referenced. Safety-process interfaces remain in scope.
Read the cited document’s applicability and the project certification basis.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(4)
Lists ARP4754A with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(1)
Lists ED-79A with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting sourceReferences this edition
Source-backedEvidence and scope
AMC 20-152A §8(c)(5)
Lists ARP4761 with the dated edition shown in the source.
Related industry-material citation, distinct from the ED-80/DO-254 recognition in §1.2.
Supporting source