FAA Advisory circularActive — selected source checked

AC 20-115D

Airborne Software Development Assurance Using EUROCAE ED-12( ) and RTCA DO-178( )

20-115D · 2017-07-21 Source checked 2026-11-28

Scope, source and reading notes

This AC recognises DO-178C/ED-12C, DO-330/ED-215 and the model-based, object-oriented and formal-methods supplements. Apply the relevant provisions to the software and certification context.

Aerospace Consulting reference note: Software development assurance and recognition of DO-178C/ED-12C, its supplements and tool qualification guidance.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5597a1af49c872a1a843c05601742ddcc8e8a190642f31e3cb9ce8e0dc63d91e

Source page 8 · PDF page 8

(1) Assess the legacy software to be modified or re-used for its usage history from previous installations. If the software has safety-related service difficulties, airworthiness directives, or open problem reports with a potential safety impact on the proposed installation, establish plans to resolve all related software deficiencies. Prior to modifying or reusing the legacy software, correct any related development process deficiencies, such as those discovered during internal or external audits or reviews, or identified in open problem report(s) resulting in non-satisfaction to one or more ED-12B/DO-178B objectives. Evidence of resolution and closure of all process-related open problem reports and of all process-related audit or review findings may be requested.

(2) The system safety process assigns the minimum development assurance level based on the severity classifications of failure conditions for a given function. The ED-12B/DO-178B software levels are consistent with the ED-12C/DO-178C software levels. However, ED-12/DO- 178 and ED-12A/DO-178A were published prior to establishment of the levels addressed in ED- 12B/DO-178B and ED-12C/DO-178C. Use Table 1 to determine if your legacy software level satisfies the software level assigned by the system safety process for the proposed installation. A “” in the intersection of the row and column indicates that the legacy software level is acceptable. For example, legacy software with development assurance to ED-12A/DO-178A Level 2 can be considered to satisfy software Levels B, C, and D. A blank indicates that the software level is not acceptable. Therefore, the ED-12A/DO-178A software developed to Level 2 would not be acceptable where software Level A is required.

Table 1 – Software Level Relationships

Legacy Software Level

Legacy Software Level

Assigned

per ED-12B/

per ED-12A/

Legacy Software Level per ED-12/DO-178

Software

DO-178B

DO-178A

Level

A B C D 1 2 3 Critical Essential Non- Essential A   

B     

C       

D        

(a) If your legacy software was developed to software Level Essential using ED- 12/DO-178 and was previously accepted by the certification authority as acceptable for software Level B, it remains acceptable for the new project. If the ED-12/DO-178 legacy software was not previously assessed, or the software level is not acceptable, upgrade the software development baseline, including all processes and procedures (including tool qualification processes), using section 12.1.4 of ED-12C/DO-178C, and ED-215/DO-330.

(b) If your legacy software was developed using ED-12A/DO-178A, and the software level is not acceptable, upgrade the software development baseline, including all

View figures, tables and original page layoutOriginal source page Source page 8 · PDF page 8 of AC 20-115D

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-115D

Related technical context

Engineering context
Evidence and scope

AC 20-115D and AMC 20-115D — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.