FAA Advisory circularActive — selected source checked

AC 20-115D

Airborne Software Development Assurance Using EUROCAE ED-12( ) and RTCA DO-178( )

20-115D · 2017-07-21 Source checked 2026-11-28

Scope, source and reading notes

This AC recognises DO-178C/ED-12C, DO-330/ED-215 and the model-based, object-oriented and formal-methods supplements. Apply the relevant provisions to the software and certification context.

Aerospace Consulting reference note: Software development assurance and recognition of DO-178C/ED-12C, its supplements and tool qualification guidance.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 5597a1af49c872a1a843c05601742ddcc8e8a190642f31e3cb9ce8e0dc63d91e

Source page 10 · PDF page 10

(7) If you want to use your existing processes to make modifications to your legacy software using the version of ED-12( )/DO-178( ) (i.e., ED-12/DO-178, ED-12A/DO-178A, or ED-12B/DO-178B) that was used for the original software approval, you may do so provided all of the following conditions are met:

(a) If model-based development, object-oriented technology, or formal methods will be used, existing processes incorporating these methods were evaluated and found to be acceptable by the FAA on a previous certified project. These processes should have been developed in accordance with the FAA guidance specific to the technique, such as that contained in associated issue paper or published advisory circular.

(b) You have maintained, and can still use, the software plans, processes, and life cycle environment, including improvements to processes or to the life cycle environment as captured in revised plans.

(c) You do not intend to declare the proposed software as having satisfied ED- 12C/DO-178C.

(8) If the conditions in subparagraph 9.b.(7) are satisfied:

(a) You may accomplish all modifications to the software using the same ED-12()/ DO-178( ) version as the original approval. However, you may not declare your software as equivalent to satisfying ED-12C/DO-178C.

(b) If using configuration data, as defined under “Parameter Data Item” in ED- 12C/DO-178C, you may use existing processes for such data if the processes were evaluated and found to be acceptable by the FAA on a previous project. In the absence of processes for using configuration data, you should establish new processes for using parameter data items in accordance with ED-12C/DO-178C.

(9) If any of the conditions in subparagraph 9.b.(7) are not satisfied, update all your processes and procedures (including tool qualification processes), using ED-12C/DO-178C and ED-215/DO-330, and make all modifications to the software using section 12.1 of ED-12C/DO- 178C. If you want to declare your software as equivalent to satisfying ED-12C/DO-178C, your declaration applies to both modified and unmodified software and is valid even if you use unmodified tools that have not been qualified using ED-12C/DO-178C and ED-215/DO-330. However, you cannot declare your unmodified tools as equivalent to having satisfied ED- 12C/DO-178C and ED-215/DO-330. All subsequent modifications to all your software and tools are to be made using your processes and procedures that satisfy ED-12C/DO-178C and ED- 215/DO-330.

10. Tool Qualification. Section 12.2 of ED-12C/DO-178C, and ED-215/DO-330 provide an acceptable method for tool qualification. ED-215/DO-330 contains its own complete set of objectives, activities, and life cycle data for tool qualification.

a. If your legacy software was previously approved using ED-12/DO-178 or ED-12A/DO- 178A, and you intend to use a new or modified tool for modifications to the legacy software, use the criteria of section 12.2 of ED-12C/DO-178C to determine if tool qualification is needed. If

View figures, tables and original page layoutOriginal source page Source page 10 · PDF page 10 of AC 20-115D

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AMC 20-115D

Related technical context

Engineering context
Evidence and scope

AC 20-115D and AMC 20-115D — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.