FAA Special-class airworthiness criteriaFinal

Archer M001 criteria

Special Class Airworthiness Criteria for the Archer Aviation Model M001 Powered-Lift

Final · 24 May 2024; correction · 31 May 2024 Source checked 2026-11-28

Scope, source and reading notes

Airworthiness criteria established under 14 CFR 21.17(b) for the Archer M001. This is a special-class certification basis, distinct from a special condition or issue paper.

Aerospace Consulting reference note: Published final powered-lift certification criteria for the M001, including aircraft, engine and propeller provisions.

Reading text follows the official Federal Register HTML article. The original PDF may include adjacent notices on shared printed pages. Reading sections are not PDF page numbers.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: e92d4cf0985647a55aa64fce93963034590de1c5e6037d1a71fe08a2cade3bca

Federal Register page 45970

(2) Materials in the baggage and cargo compartments inaccessible in flight. (b) The following materials must be flame resistant-- (1) Materials in each compartment accessible in flight; and (2) Any equipment associated with any electrical cable installation and that would overheat in the event of circuit overload or fault. (c) Thermal/acoustic materials in the fuselage, if installed, must not be a flame propagation hazard. (d) Sources of heat within each baggage and cargo compartment that are capable of igniting adjacent objects must be shielded and insulated to prevent such ignition. (e) Each baggage and cargo compartment must-- (1) Be located where a fire would be visible to the pilots and be accessible for the manual extinguishing of a fire, (2) Be equipped with a smoke or fire detection system that warns the pilot, or (3) Be constructed of, or lined with, fire resistant materials. (f) There must be a means to extinguish any fire in the cabin such that the pilot, while seated, can easily access the fire extinguishing means. (g) Each area where flammable fluids or vapors might escape by leakage of a fluid system must-- (1) Be defined; and (2) Have a means to minimize the probability of fluid and vapor ignition, and the resultant hazard, if ignition occurs.

AM1.2330 Fire Protection in Fire Zones and Adjacent Areas

(a) Flight controls, engine mounts, and other flight structures within or adjacent to fire zones must be capable of withstanding the effects of a fire. (b) Engines in a fire zone must remain attached to the aircraft in the event of a fire. (c) In fire zones, terminals, equipment, and electrical cables used during emergency procedures must perform their intended function in the event of a fire.

AM1.2335 Lightning and Static Electricity Protection

(a) The aircraft must be protected against catastrophic effects from lightning. (b) The aircraft must be protected against hazardous effects caused by an accumulation of electrostatic charge.

Subpart E--Powerplant

AM1.2400 Powerplant Installation

(a) For the purpose of this subpart, the aircraft powerplant installation must include each component necessary for propulsion, which affects propulsion safety. (b) Each aircraft engine and propeller must be approved under the aircraft type certificate using standards found in subparts H and I. (c) The applicant must construct and arrange each powerplant installation to account for-- (1) Likely operating conditions, including foreign-object threats; (2) Sufficient clearance of moving parts to other aircraft parts and their surroundings; (3) Likely hazards in operation including hazards to ground personnel; and (4) Vibration and fatigue. (d) Hazardous accumulations of fluids, vapors, or gases must be isolated from the aircraft and personnel compartments and be safely contained or discharged. (e) Powerplant components must comply with their component limitations and installation instructions or be shown not to create a hazard.

AM1.2405 Power or Thrust Control Systems

(a) Any power or thrust control system or powerplant control system must be designed so no unsafe condition results during normal operation of the system. (b) Any single failure or likely combination of failures or malfunctions of a power or thrust control system or powerplant control system must not prevent continued safe flight and landing of the aircraft. (c) Inadvertent flightcrew operation of a power or thrust control system or powerplant control system must be prevented, or if not prevented, must not prevent continued safe flight and landing of the aircraft.

Sec. 23.2410 Powerplant Installation Hazard Assessment

(a) through (c) [Applicable to Model M001]

Sec. 23.2415 Powerplant Ice Protection

(a) through (b) [Applicable to Model M001]

AM1.2425 Powerplant Operational Characteristics

(a) Each installed powerplant must operate without any hazardous characteristics during normal and emergency operation within the range of operating limitations for the aircraft and the engine. (b) The design must provide for the shutdown and restart of the powerplant in flight within an established operational envelope.

AM1.2430 Energy Systems

(a) Each energy system must-- (1) Be designed and arranged to provide independence between multiple energy-storage and supply systems, so that failure of any one component in one system will not result in loss of energy storage or supply of another system; (2) Be designed to prevent catastrophic events due to lightning strikes, taking into account direct and indirect effects on the aircraft; (3) Provide the energy necessary to ensure each powerplant functions properly in all likely operating conditions; (4) Provide the flightcrew with a means to determine the total useable energy available and provide uninterrupted supply of that energy when the system is correctly operated, accounting for likely energy fluctuations; (5) Provide a means to safely remove or isolate the energy stored in the system from the aircraft; and (6) Be designed to retain energy under all likely operating conditions and to minimize hazards to occupants and first responders following an emergency landing or otherwise survivable impact (crash landing). (b) Each energy-storage system must-- (1) Withstand the loads under likely operating conditions without failure; and (2) Be isolated from personnel compartments and protected from likely hazards. (c) Each energy-storage recharging system must be designed to-- (1) Prevent improper recharging; and (2) Prevent the occurrence of hazard to the aircraft or to persons during recharging.

AM1.2440 Powerplant Fire Protection

There must be means to isolate and mitigate hazards to the aircraft in the event of a powerplant system fire or overheat in operation.

Subpart F--Equipment

Sec. 23.2500 Airplane Level Systems Requirements

(a) through (b) [Applicable to Model M001]

Sec. 23.2505 Function and Installation

[Applicable to Model M001]

Sec. 23.2510 Equipment, Systems, and Installations

(a) through (c) [Applicable to Model M001]

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 21.17-4

Related technical context

Engineering context
Evidence and scope

AC 21.17-4 and Archer M001 criteria — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.