AMC 20-158A

Aircraft electrical and electronic system high-intensity radiated fields (HIRF) protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems, including all three appendices.

Aerospace Consulting reference note: Provides the HIRF protection framework and supporting environmental, transfer-function and safety-assessment guidance.

Complete selected AMC and associated material, from PDF pages 518–559 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 557 · PDF page 557

Example 5

Function 25.1317(a) System Channel Channel Channel Channel Provide electrical power for

Active

Active

Passive-backup

(Left engine

(Right engine

electrical and electronic systems including those with catastrophic failure

generator

generator

(Emergency power supply

conditions

system)

system)

driven by ram-air turbine)

Active (APU-driven generator system required for ETOPS flight beyond 180')

(a)(1), (a)(2),

(a)(1), (a)(2),

(b)

Requirements for compliance demonstration

(a)(3)

(a)(3)

(a)(1), (a)(2), (a)(3)

(CS 25.1317)

Discussion: This example depicts a twin-engined transport category aircraft electrical system where two or more independent sources of electrical power are required by CS 25.1307(b) and an alternate source (driven by a ram-air turbine) is necessary to meet the safety objectives of CS 25.1309 and CS 25.1351(d). This configuration includes a third electrical power source driven by an auxiliary power unit (APU). This third source is required (active channel) for ETOPS beyond 180 minutes. As in Example 4, the emergency power source is a passive-backup channel provided by a ram-air turbine that remains stowed during normal flight and deployed either automatically and/or manually when power from all other channels is lost. All active electrical power generation channels should comply with CS 25.1317(a)(1), (a)(2), and (a)(3). The passive-backup electrical power generation channel does not mitigate the adverse effects due to HIRF exposure to meet the intent of the HIRF requirements. It is acceptable that the passive-backup channel demonstrate compliance with CS 25.1316(b) requirements. Note: For non-ETOPS or for ETOPS up to 180' aircraft, the APU HIRF certification level should be defined based on the specific aircraft safety assessment.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-158B

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.