EASA Acceptable Means of ComplianceFinal — current published edition checked

AMC 20-158A

Aircraft electrical and electronic system high-intensity radiated fields (HIRF) protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

HIRF protection for aircraft electrical and electronic systems, including all three appendices.

Aerospace Consulting reference note: Provides the HIRF protection framework and supporting environmental, transfer-function and safety-assessment guidance.

Complete selected AMC and associated material, from PDF pages 518–559 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 529 · PDF page 529

Figure 2: Aircraft low-level coupling tests — Level A systems

(n) = Step number as described in Section 7 of this AMC

7. STEPS TO DEMONSTRATE ‘LEVEL A’ SYSTEM HIRF COMPLIANCE

Figures 1 and 2 illustrate a process that the applicant can use to demonstrate that their Level A system complies with CS 23.1308(a), 25.1317(a), 27.1317(a), and 29.1317(a).

a. Step 1 — HIRF safety assessment

1. The applicant should determine the system failure condition classification for the systems to be certified on their aircraft, using a system safety assessment as discussed in Section 6(b)(2). For systems classified with catastrophic failure conditions (Level A systems), the applicant should follow compliance steps 2 to 15 listed below, as appropriate. These compliance steps are also depicted in Figures 1 and 2 of this AMC, and are not necessarily accomplished sequentially. Applicants for systems classified with hazardous or major failure conditions (HIRF certification Level B and Level C systems) should follow the compliance steps outlined in Section 8 of this AMC.

View figures, tables and original page layoutOriginal source page Source page 529 · PDF page 529 of AMC 20-158A

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-158B

Related technical context

Engineering context
Evidence and scope

AC 20-158B and AMC 20-158A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.