EASA Acceptable Means of ComplianceFinal — current published edition checked

AMC 20-136A

Aircraft Electrical and Electronic System Lightning Protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection, including both appendices.

Aerospace Consulting reference note: Provides guidance for assessing lightning effects, assigning protection levels and demonstrating protection of aircraft electrical and electronic systems.

Complete selected AMC and associated material, from PDF pages 464–496 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 471 · PDF page 471

3. Level A systems. The specifications in CS 23.1306/2515(a), 25.1316(a), 27.1316(a), and 29.1316(a) address the adverse effects on the aircraft functions and systems that perform functions whose failure would prevent the continued safe flight and landing of the aircraft. When demonstrating compliance with CS 23.1306(a), 25.1316(a), 27.1316(a), and 29.1316(a), the electrical and electronic system is the one required to perform the function whose failure would prevent continued safe flight and landing. This electrical and electronic system must also automatically recover normal operation of theLevel A functions in a timely manner to comply with CS 23.1306(a)(2), 25.1316(a)(2), 27.1316(a)(2), and 29.1316(a)(2). If all equipment and components of the system required for the normal operation of the Level A functions are not susceptible when complying with paragraphs (a)(1) and (a)(2), then it is acceptable that the equipment and components only for non- normal situations do not show compliance with the requirements of paragraph (a). In this case, it is considered acceptable that equipment and components of the system required only for non-normal situations show compliance at least with the requirements of paragraph (b) as a Level B system.

The lightning safety assessment should consider the effects of lightning-related failures or malfunctions on systems with lower failure classifications that may affect the function of Level A systems. The applicant should demonstrate that any system with wiring connections to a Level A system will not adversely affect the functions with catastrophic failure conditions performed by the Level A system when the aircraft is exposed to lightning. Redundancy alone cannot protect against lightning because the lightning-generated electromagnetic fields, conducted currents and induced currents in the aircraft can simultaneously induce transients in all the electrical wiring on an aircraft.

4. Level B or Level C systems. Simultaneous and common-cause failures due to lightning exposure generally do not have to be assumed for systems, incorporating redundant, spatially separated installations in the aircraft. If such systems were assigned a Level B or C, the failure of these systems would reduce the capability of the aeroplane or the ability of the flight crew to respond to an adverse operating condition. This is because aircraft transfer function tests and in-service experience have shown that these redundant and spatially separated installations are not simultaneously exposed to the maximum lightning-induced transients. Therefore, the simultaneous loss of all these redundant and spatially separated Level B or Level C systems due to lightning exposure does not need to be considered. However, if multiple systems and their wirings, whose failure would reduce the capability of the aeroplane or the ability of the flight crew to respond to an adverse operating condition, are installed within the same location in the aircraft, or share a common wiring connection, then the combined failure due to lightning exposure should be assessed to determine whether the combined failures are catastrophic. If so, these systems should be designated as Level A systems.

5. Failure conditions. The lightning safety assessment should consider all the potential adverse effects due to system failures, malfunctions, or misleading information. The lightning safety assessment may show that some systems have different failure conditions in different phases of flight; therefore, the system LCL corresponds to the most severe failure condition. For example, an automatic flight control system may have a catastrophic failure condition for autoland, while automatic flight control system operations in cruise may have a hazardous failure condition.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-136C

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.