25-852-SC
Operation Without Normal Electrical Power — Gulfstream G700/G800
Final · 2024-01-30 Source checked 2026-11-28
Scope, source and reading notes
Applies to Gulfstream GVIII-G700 and GVIII-G800 electronic flight-control designs. A project-specific special condition, not a generally applicable requirement.
Aerospace Consulting reference note: Electrical power availability and continued safe flight and landing for electrically dependent flight controls.
Reading text follows the official Federal Register HTML article. The original PDF may include adjacent notices on shared printed pages. Reading sections are not PDF page numbers.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 8a058c71452435765168e757d0418302d41bc8b12e829b25159a14c465a7ff9f
require the applicant to demonstrate that the airplane has the power required for continued safe flight and landing with the use of its emergency electrical power systems. These emergency electrical power systems must be able to power all loads considered essential for continued safe flight and landing. These special conditions contain the additional safety standards that the Administrator considers necessary to establish a level of safety equivalent to that established by the existing airworthiness standards.
Applicability
As discussed above, these special conditions are applicable to the Gulfstream Model GVIII-G700 and GVIII-G800 series airplanes. Should Gulfstream apply at a later date for a change to the type certificate to include another model incorporating the same novel or unusual design feature, these special conditions would apply to that model as well.
Conclusion
This action affects only a certain novel or unusual design feature on Gulfstream Model GVIII-G700 and GVIII-G800 series of airplanes. It is not a rule of general applicability.
List of Subjects in 14 CFR Part 25
Aircraft, Aviation safety, Reporting and recordkeeping requirements.
Authority Citation
The authority citation for these special conditions is as follows:
Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702, and 44704.
The Special Conditions
[ssquf] Accordingly, pursuant to the authority delegated to me by the Administrator, the following special conditions are issued as part of the type certification basis for Gulfstream Model GVIII-G700 and GVIII-G800 series airplanes. Because the total loss of normal, generated, electrical power in two-engine airplanes is not extremely improbable, and because the loss of all electrical power may be catastrophic to airplanes equipped with an electronic flight-control system, the following special conditions apply to Gulfstream Model GVIII-G700 and GVIII-G800 airplanes. (a) In lieu of Sec. 25.1351(d), the following special conditions apply: (1) Gulfstream must show, by test or a combination of test and analysis, that the airplane is capable of continued safe flight and landing with all normal electrical power sources inoperative, as prescribed by paragraphs (1)(i) and (1)(ii), below. For purposes of these special conditions, normal sources of electrical-power generation do not include alternate power sources such as the battery, ram-air turbine, or independent power systems such as the flight-control permanent-magnet generating system. In showing capability for continued safe flight and landing, Gulfstream must account for systems capability, effects on crew workload and operating conditions, and the physiological needs of the flightcrew and passengers for the longest diversion time for which Gulfstream is seeking approval. (i) In showing compliance with this requirement, Gulfstream must account for common-cause failures, cascading failures, and zonal physical threats. (ii) Gulfstream may consider the ability to restore operation of portions of the electrical power generation and distribution system if it can be shown that unrecoverable loss of those portions of the system is extremely improbable. The design must provide an alternative source of electrical power for the time required to restore the minimum electrical-power generation capability required for safe flight and landing. Gulfstream may exclude unrecoverable loss of all engines when showing compliance with this requirement. (2) Regardless of electrical-power generation and distribution- system recovery capability shown under special condition (1), above, sufficient electrical-system capability must be provided to: (i) Allow time to descend, with all engines inoperative, at the speed that provides the best glide distance, from the maximum operating altitude to the top of the engine-restart envelope, and (ii) Subsequently allow multiple start attempts of the engines and auxiliary power unit (APU). The design must provide this capability in addition to the electrical capability required by existing part 25 requirements related to operation with all engines inoperative. (3) The airplane emergency electrical-power system must be designed to supply: (i) Electrical power required for immediate safety, which must continue to operate without the need for crew action following the loss of the normal electrical power, for a duration sufficient to allow reconfiguration to provide a non-time-limited source of electrical power. (ii) Electrical power required for continued safe flight and landing for the maximum diversion time. (4) If the applicant uses APU-generated electrical power to satisfy the requirements of these special conditions, and if reaching a suitable runway for landing is beyond the capacity of the battery systems, then the APU must be able to be started under any foreseeable flight condition prior to the depletion of the battery, or the restoration of normal electrical power, whichever occurs first. Flight tests must demonstrate this capability at the most critical condition. (i) The applicant must show that the APU will provide adequate electrical power for continued safe flight and landing. (ii) The airplane flight manual (AFM) must incorporate abnormal procedures that direct the pilot to take appropriate actions to activate the APU after loss of normal engine-driven generated electrical power. (5) As part of showing compliance with these special conditions, the tests to demonstrate loss of all normal electrical power must also take into account the following: (i) The assumption that the failure condition occurs during night instrument meteorological conditions (IMC) at the most critical phase of the flight, relative to the worst possible electrical-power distribution and equipment-loads-demand condition. (ii) After an unrestorable loss of normal engine-driven generated electrical power, the airplane engine-restart capability is provided, and operations are continued in IMC. (iii) The airplane is demonstrated to be capable of continued safe flight and landing. The duration of this capability must be computed based on the maximum diversion-time capability for which the airplane is being certified. The applicant must account for airspeed reductions resulting from the associated failure or failures. (iv) The airplane must provide adequate indication of loss of normal electrical power to direct the pilot to the abnormal procedures, and the AFM must incorporate abnormal procedures that will direct the pilot to take appropriate actions.
Issued in Kansas City, Missouri, on January 24, 2024. Patrick R. Mullen, Manager, Technical Innovation Policy Branch, Policy and Innovation Division, Aircraft Certification Service. [FR Doc. 2024-01740 Filed 1-29-24; 8:45 am] BILLING CODE 4910-13-P
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 25.671-1 and 25-852-SC — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source