EASA Acceptable Means of ComplianceFinal — current published edition checked

AMC 20-136A

Aircraft Electrical and Electronic System Lightning Protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection, including both appendices.

Aerospace Consulting reference note: Provides guidance for assessing lightning effects, assigning protection levels and demonstrating protection of aircraft electrical and electronic systems.

Complete selected AMC and associated material, from PDF pages 464–496 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 490 · PDF page 490

Equipment transient design level (ETDL): the peak amplitude of transients to which equipment is qualified.

Function: the specific action of a system, equipment, and flight crew performance aboard the aircraft that, by itself, provides a completely recognisable operational capability. For example, ‘display aircraft heading to the pilots’ is a function. One or more systems may perform a specific function, or one system may perform multiple functions.

External environment: the natural lightning environment, outside the aircraft, for design and certification purposes. See SAE ARP 5412B / EUROCAE ED-84A, which references documents that provide additional guidance on aircraft lightning environments and the related waveforms.

Immunity: the capacity of a system or piece of equipment to continue to perform its intended function, in an acceptable manner, in the presence of RF fields.

Indirect effects: electrical transients induced by lightning in aircraft electrical or electronic circuits.

Internal environment: the electric and magnetic fields, currents, and voltages on and within the aircraft produced by a lightning strike to the aircraft.

Lightning flash: the total lightning event. It may occur in a cloud, between clouds, or between a cloud and the ground. It can consist of one or more return strokes, plus intermediate or continuing currents.

Lightning strike: attachment of the lightning flash to the aircraft.

Lightning strike zones: aircraft surface areas and structures that are susceptible to lightning attachment, dwell times, and current conduction. See SAE ARP 5414B / EUROCAE ED-91A, which references documents that provide additional guidance on aircraft lightning zoning.

Lightning stroke (return stroke): a lightning current surge that occurs when the lightning leader (the initial current charge) makes contact with the ground or another charge centre. A charge centre is an area of high potential of opposite charge.

Margin: the difference between the equipment transient design levels and the actual transient level.

Multiple burst: a randomly spaced series of bursts of short duration, low-amplitude current pulses, with each pulse characterised by rapidly changing currents. These bursts may result as the lightning leader progresses or branches, and are associated with the cloud-to-cloud and intra-cloud flashes. The multiple bursts appear most intense when the initial leader attaches to the aircraft. See SAE ARP 5412B / EUROCAE ED-84A.

Multiple stroke: two or more lightning return strokes during a single lightning flash. See SAE ARP 5412B / EUROCAE ED-84A.

Non-normal situation: any situation that requires non-normal, abnormal, emergency, or unusual procedures, or configurations for operating an aircraft.

Normal operation: a status where the system is performing its intended function. When addressing compliance with CS 23.1306/2515(a)(2), 25.1316(a)(2), 27.1316(a)(2), and 29.1316(a)(2), the function whose failure would prevent the continued safe flight and landing should be in the same undisturbed state as before exposure to the lightning threat while other functions, performed by the same system, subject to CS 23.1306/2515(b), 25.1316(b), 27.1316(b), and 29.1316(b), are not required to be recovered. The system that performs the function may be nevertheless in a different state as long as the function is not adversely affected.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-136C

Related technical context

Engineering context
Evidence and scope

AC 20-136C and AMC 20-136A — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference