EASA Acceptable Means of ComplianceFinal — current published edition checked

AMC 20-136A

Aircraft Electrical and Electronic System Lightning Protection

Current AMC; incorporated in AMC-20 Amendment 23 Source checked 2026-11-28

Scope, source and reading notes

Aircraft electrical and electronic system lightning protection, including both appendices.

Aerospace Consulting reference note: Provides guidance for assessing lightning effects, assigning protection levels and demonstrating protection of aircraft electrical and electronic systems.

Complete selected AMC and associated material, from PDF pages 464–496 of the AMC-20 consolidation. The original PDF contains the whole consolidation. Reading text is extracted; original figures and layout remain available.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: EASA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: b3d02d6ad4cd2833f79be85634221f52ea8bd90a84c733257193e4a60a2d536a

Source page 477 · PDF page 477

b. Step 2 — Define aircraft and system lightning protection. The applicant should define the lightning protection features to be incorporated into the aircraft and system designs, based on the lightning environments that are applicable to their aircraft and its Level A systems. Equipment, system, and aircraft lightning protection design may occur before aircraft-level tests are performed, and before the actual internal lightning environment is determined. Therefore, the equipment, system and aircraft lightning protection design should be based on an estimate of the expected internal lightning environment.

c. Step 3 — Establish the system’s ETDLs. The applicant should establish the aircraft system’s ETDLs from an evaluation of expected lightning transient amplitudes and waveforms for the system installation, structure and wiring configuration on a specific aircraft. ETDLs that exceed the ATLs by an acceptable margin should be established. In general, the ETDLs for equipment in a complex system will not be the same for all wire bundles connecting them to other equipment in the system. The applicant may use the results of lightning tests on existing similar aircraft, engineering analyses, or knowledgeable estimates to establish the appropriate system’s ETDLs. While specific aircraft configurations and system installations may lead to ETDLs that have amplitudes and waveforms different from those defined in EUROCAE ED-14G Section 22, ETDLs are often specified using the information from Section 22. The ETDLs must exceed the ATLs by an acceptable margin.

d. Step 4 — Select the ETDL verification method. The applicant should determine whether to perform system qualification tests on the Level A system, or whether to base the system verification on previous system qualification tests performed on a similar system.

e. Step 5 — Verify the system’s ETDLs using system qualification tests

1. Equipment test. Lightning induced transient susceptibility tests (Tolerance Damage and Functional Upset) of RTCA / DO-160G / EUROCAE ED-14G (or latest version) Section 22 may be used to build confidence in the equipment’s lightning immunity before conducting integrated system qualification tests. Equipment tests may be used to augment the system qualification tests where appropriate. For equipment whose lightning immunity is evaluated as part of the system qualification tests, the individual equipment’s lightning testing described in this step is optional.

2. The applicant should identify the equipment, components, sensors, power systems, and wiring associated with the Level A system undergoing ETDL verification tests, specifically considering the system functions whose failures would have catastrophic consequences. For complex Level A systems, the system configuration may include redundant equipment, multiple power sources, multiple sensors and actuators, and complex wire bundles. The applicant should define the system configuration used for the ETDL verification tests. The applicant should obtain the Agency’s acceptance of their system configuration for ETDL verification tests.

3. If the Level A System consists of multiple similar channels, the applicant can propose using one or more channels in the laboratory test set-up for the integrated system, instead of all similar channels. The applicant should demonstrate that the laboratory test set-up adequately performs the functions that must demonstrate compliance with CS 23.1306/2515(a), 25.1316(a), 27.1316(a), and 29.1316(a). The applicant should ensure that the laboratory test set-up represents and monitors

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 20-136C

Related technical context

Engineering context