FAA Advisory circularActive

AC 25.1322-1

Flightcrew Alerting

25.1322-1 Source checked 2026-11-28

Scope, source and reading notes

Design approval of flightcrew-alerting functions under Part 25, particularly § 25.1322.

Aerospace Consulting reference note: Addresses flightcrew-alerting philosophy, prioritization, presentation, and evaluation for transport category airplanes.

The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.

Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.

Official source recordOriginal PDF on this site

Source: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: d58f98b67c7584f441ff3821462227c623ada6ada18e29851c1c5b75395c5c00

Source page 7 · PDF page 7

12/13/2010 AC 25.1322-1

the requirements listed in § 25.1322(b) and § 25.1322(c)(1). If an alert’s urgency and prioritization is context-sensitive, state what information should be considered (for example, the priority associated with different alerting conditions may vary depending on the state of the airplane, phase of flight, system configuration, etc.).

(11) Presentation. Establish a consistent alert presentation scheme (for example, location of the alert on the flight deck, alert combinations [aural, visual, tactile], information presented in the alert message, and color and graphical coding standardization). Also, determine the format in which that alert will be presented (for example, structure and timing of alert messages) to support the alerting function’s purpose.

6. Alert Functional Elements. The functional elements used in the alerting and information functions for warning and caution alerts must provide timely attention-getting cues, resulting in immediate flightcrew awareness, through at least two different senses (§ 25.1322(c)(2)). Functional elements used for advisory alerts do not require immediate flightcrew awareness and are normally provided through a single sense.

a. Warning Alerts. Several alert functional element combinations are used to comply with § 25.1322(c)(2) (two-senses requirement). The typical alert-element combinations for warning alerts (not including time-critical warning alerts) are shown below.

(1) Master visual alert, visual alert information, and master aural alert.

(2) Master visual alert, visual-alert information, and voice-alert information or unique alert tone.

Note 1: Voice-alert information may be preceded by a master aural alert.

Note 2: A tactile alert may be combined with a visual or aural alert to meet the § 25.1322 requirement for a combination of two senses. b. Time-Critical Warning Alerts. Some warnings may be so time-critical for the safe operation of the airplane that general alerts such as a master visual alert and a master aural alert may not provide the flightcrew with immediate awareness of the specific alerting condition that is commensurate with the level of urgency of flightcrew response necessary. In such cases, warning elements dedicated to specific alerting conditions should be provided that give the flightcrew immediate awareness without further reference to other flight deck indications. Examples of such time-critical warnings include reactive windshear and ground proximity. The alerting elements for time-critical warnings should include:

 Unique voice information or unique tone, or both, for each alerting condition, and  Unique visual alert information in each pilot’s primary field of view for each alerting condition.

Connected references

Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.

AC 25.1302-1

Related technical context

Engineering context
Evidence and scope

AC 25.1302-1 and AC 25.1322-1 — published scope

Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.

This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.

Supporting source

Copy reference

Select and copy the citation below.