AC 25.1322-1
Flightcrew Alerting
25.1322-1 Source checked 2026-11-28
Scope, source and reading notes
Design approval of flightcrew-alerting functions under Part 25, particularly § 25.1322.
Aerospace Consulting reference note: Addresses flightcrew-alerting philosophy, prioritization, presentation, and evaluation for transport category airplanes.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: d58f98b67c7584f441ff3821462227c623ada6ada18e29851c1c5b75395c5c00
12/13/2010 AC 25.1322-1 Appendix 2
(3) We recommend automatic volume control to maintain an acceptable signal-to-noise ratio.
c. Number of Sounds.
(1) Limit the number of different master aural alerts and unique tones, based on the ability of the flightcrew to readily obtain information from each alert and tone. While different studies have resulted in different answers, in general these studies conclude that the number of unique tones should be less than 10.
(2) Provide one unique tone for master warning alerts and one unique tone for master caution alerts.
(3) We do not recommend a master aural alert for advisories because immediate flightcrew attention is not needed for an advisory alert.
d. Onset/Duration.
(1) The onset of the master aural alert or unique tone should occur in a timeframe appropriate for the alerting condition and the desired response. Any delays between the onset of the master aural alert or unique tone and its related visual alert should not cause flightcrew distraction or confusion.
(2) We recommend ramping the onset and offset of any aural alert or unique tone to avoid startling the flightcrew.
(a) A duration for onsets and offsets of 20-30 milliseconds is acceptable.
(b) An onset level of 20-30 decibels above the ambient noise level is acceptable.
(3) If more than one source of the master aural alert or unique tone is provided, the master aural alert or unique tone for the same condition should occur simultaneously at each pilot’s station. Any timing differences should not be distracting nor should they interfere with identifying the aural alert or unique tone.
(4) Signal duration of the master aural alert and unique tones should vary, depending on the alert urgency level and the type of response desired.
(5) Unique tones associated with time-critical warnings and cautions should be repeated and non-cancelable until the alerting condition no longer exists (for example, stall warning), unless it interferes with the flightcrew’s ability to respond to the alerting condition.
(6) Unique tones associated with warnings and cautions should be repeated and non-cancelable if the flightcrew needs continuous awareness that the condition still exists, to support them in taking corrective action. The aural warning requirements listed in §§ 25.1303(c)(1) and 25.729(e) must be followed.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 25.1302-1 and AC 25.1322-1 — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source