AC 23.1309-1E
System Safety Analysis and Assessment for Part 23 Airplanes
23.1309-1E Source checked 2026-11-28
Scope, source and reading notes
Legacy Part 23 system-safety guidance for § 23.1309 through Amendment 23-62; apply the certification basis appropriate to the project.
Aerospace Consulting reference note: System safety analysis and assessment for equipment, systems, and installations on small airplanes, including failure-condition classification and compliance considerations.
The complete selected publication is available in reading text and as the original PDF. Reading text is extracted from the official PDF; page layout is simplified, and figures and tables should be checked in the original page view.
Search covers extracted text. Words contained only in graphics may not be searchable. The original publication is available below.
Official source recordOriginal PDF on this siteSource: FAA. Reproduced with source acknowledgment; source edition and status are shown above. SHA-256: 2a3aa2965f13ddb9fa917b3b1a406c66ad0cce0a04424e3ce3197b183c0a2495
(3) There may be significant difference in the guidance provided on the use of system architecture for appropriate determination of the DALs between this AC and guidelines contained in ARP 4754A. Where apparent differences exist between this AC and ARP 4754A, this AC takes precedence. The FAA recognizes that consideration of system architecture for determining DALs is appropriate and may lead to lower levels in some specific cases. Figure 2 in this AC already allows reduction of software and complex hardware DALs for Class I, II, and III airplanes; therefore, no additional reductions from these levels are permitted without the Small Airplane Directorate approval or there is established specific policy or guidance. If the Small Airplane Directorate has established specific guidance or policy for these levels, then the approval can made by the ACO. For commuter category airplanes, the guidance in ARP 4754A is more likely to be appropriate since its DALs are higher. There may be acceptability only if additional credit for architecture is requested for hazardous or catastrophic failure conditions in Class IV, commuter category airplanes.
f. Equipment installed in part 23 airplanes that performs functions addressed by TSO standards. Equipment installed in part 23 airplanes that performs functions addressed by TSO standards should meet applicable TSO standards. FAA prefers the equipment meet design approval of the functional TSO. However, the equipment is not required to have TSO authorization, but it would need to meet other equivalent minimum performance standards acceptable to the Administrator. The TSO data should include the equipment complex hardware and software DALs. For both TSO and non-TSO equipment, the safety assessment and figure 2 should be used to check the complex hardware and software DALs against the installation requirements.
22. Electromagnetic protection for electrical/electronic systems.
Current trends indicate increasing reliance on electrical/electronic systems for safe operations. Electromagnetic effects, environmental effects, and environmental qualifications should be considered for systems that perform flight, propulsion, navigation, and instrumentation functions. The software and complex hardware DALs shown in figure 2 are not applicable for HIRF and lightning protection levels. For guidance for the protection against these effects, refer to the latest version of AC 21-16F, AC 23-17C, AC 20-136A, and AC 20-158.
Connected references
Source-backed citations and subject-based engineering context are labelled separately. These links do not establish equivalence or project acceptance.
Related technical context
Engineering contextEvidence and scope
AC 23.1309-1E and AC 25.1309-1B — published scope
Aerospace Consulting navigation suggestion based on the subject and stated scope of the two publications.
This connection does not establish regulatory equivalence, acceptance of a newer edition, or applicability of a project-specific precedent to another programme.
Supporting source