10/7/22 AC 20-152A
• Unused functions and the means (internal/external) used to deactivate them,
• Means to control any inadvertent activation of the unused functions, or inadvertent
deactivation of the used functions,
• Means to manage device resets,
• Power-on configuration,
• Clocking configuration (e.g., identification of the different clock domains), and
• Operating conditions (e.g., clock frequency, power supply level, temperature, etc.).
Objective COTS-7
The applicant should ensure that the usage of the COTS device has been defined and
verified according to the intended function of the hardware. This also includes the
hardware-software interface and the hardware to (other) hardware interface.
When a COTS device is used in a hardware DAL A or B function, the applicant should
show that unused functions of the COTS device do not compromise the integrity and
availability of the COTS device’s used functions.
Note 1: For unused functions of the COTS device, it is recommended that an effective
deactivation means is used and verified, when available.
Note 2: Verification should be performed at an appropriate level (hardware, software,
equipment).
ED-80/DO-254, Section 10.3.2.2.4 introduces hardware/software (HW/SW) interface
data, which can be used as a reference to define the software interface data of the COTS
device.
Some additional consideration should be given to the critical configuration settings.
Those are defined as the settings that are deemed necessary by the applicant for the
proper usage of the hardware, which, if inadvertently altered, could change the behavior
of the COTS device, causing it to no longer fulfill the hardware intended function.
Objective COTS-8
If the complex COTS device contributes to DAL A or B functions, the applicant should
develop and verify a means that ensures an appropriate mitigation is specified in the
event of any inadvertent alteration of the “critical configuration settings” of the COTS
device.
Note: The mitigation means might be defined at the hardware, software, or system
level, or a combination of these. The mitigation means may also be defined by the safety
assessment process.