14 CFR · AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT

§ 29.861

Fire protection of structure, controls, and other parts.

Text as of November 12, 2026

Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A) flight that would be affected by powerplant fires must be isolated under § 29.1191, or must be—

(a) For category A rotorcraft, fireproof; and

(b) For Category B rotorcraft, fireproof or protected so that they can perform their essential functions for at least 5 minutes under any foreseeable powerplant fire conditions.

[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 27-26, 55 FR 8005, Mar. 6, 1990]

About this text

Source: OFR/GPO eCFR. The wording is reproduced from the dated source, with formatting adapted for reading. The eCFR is an editorial compilation and is not the official legal edition of the CFR.

Check the latest eCFR text →

Working through a system safety question?

Bring the system, the certification basis and the issue your team needs to resolve.

Discuss your programme →