14 CFR · AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT

§ 29.1017

Oil lines and fittings.

Text as of November 12, 2026

(a) Each oil line must meet the requirements of § 29.993.

(b) Breather lines must be arranged so that—

(1) Condensed water vapor that might freeze and obstruct the line cannot accumulate at any point;

(2) The breather discharge will not constitute a fire hazard if foaming occurs, or cause emitted oil to strike the pilot's windshield; and

(3) The breather does not discharge into the engine air induction system.