Regulation text
View this edition on eCFR →Each fuel tank filler connection must prevent the entrance of fuel into any part of the airplane other than the tank itself. In addition—
(a) [Reserved]
(b) Each recessed filler connection that can retain any appreciable quantity of fuel must have a drain that discharges clear of each part of the airplane;
(c) Each filler cap must provide a fuel-tight seal; and
(d) Each fuel filling point must have a provision for electrically bonding the airplane to ground fueling equipment.
[Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-40, 42 FR 15043, Mar. 17, 1977; Amdt. 25-72, 55 FR 29785, July 20, 1990; Amdt. 25-115, 69 FR 40527, July 2, 2004]
Source: OFR/GPO eCFR. The wording is reproduced from the dated source, with formatting adapted for reading. The eCFR is an editorial compilation and is not the official legal edition of the CFR.