14 CFR · AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES

§ 25.1731

Powerplant and APU fire detector system: EWIS.

Text as of November 12, 2026

(a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant.

(b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:

(1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or

(2) Each zone involved is simultaneously protected by the same detector and extinguishing system.

(c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of § 25.1203.